Abstract In power systems, busbars connect important components such as generators, transmission lines, and loads. A typical fault occurrence on the busbar may result in isolation of faulty sections from other normally operating parts system resulting differential protection operation. Although main busbars' scheme is protection, its operation significantly affected by magnetic saturation curre...
Numerical methods for the computation of harmonic propagation and distortion differ in the manner in which they represent the harmonic sources and the system impedance. Iterative methods (e.g. harmonic load flow) use a phasor representation of these parameters. Time domain methods, on the other hand, use a time representation of the system elements and the harmonic sources. Thus, they are gener...
Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals wit...
In order to rapidly identify the source of water inrush in coal mine, and provide the theoretical basis for mine water damage prevention and control, fuzzy comprehensive evaluation model was established. The F statistics of water samples was normalized as the weight of fuzzy comprehensive evaluation for determining the source of water inrush in coal mine. The determination result of F statistic...
Stray magnetic field is one of the main issues in design of transformers, since it causes non-ideal behavior of transformers. One of the techniques is usually adopted to mitigate the unwanted stray magnetic field is the use of auxiliary windings creating a magnetic field opposite to the incident one giving rise to the reduction of the total magnetic fields. This paper presents a new mathematica...
Commutation failure is a common fault for line-commutated converters in the inverter. To reduce the possibility of commutation failure, many prediction algorithms based on alternating current (AC) voltage detection have already been implemented in high voltage direct current (HVDC) control and protection systems. Nevertheless, there are currently no effective methods to prevent commutation fail...
چکیده ندارد.
An electronic current transformer with a B-dot sensor is proposed in this study. The B-dot sensor can realize the current measurement of the transmission line in a non-contact way in accordance with the principle of magnetic field coupling. The multiple electrodes series-opposing structure is applied together with differential input structures and active integrating circuits, which can allow th...
The internal faults of transformer can be identified by various techniques. The proposed technique is by the analysis of no-load current and harmonic contents present in it. The no-load current of transformer is non-sinusoidal for sinusoidal input voltage. And hence it contains harmonics in healthy condition of transformer. But if transformer has any internal fault then the no-load current magn...