نتایج جستجو برای: monte carlo dosimetry

تعداد نتایج: 79689  

2013
Marzieh Anjomrouz Mahdi Sadeghi Asghar Haddadi

Higher initial dose rate and simplifying HDR room treatment of 169Yb element among other brachytherapy sources has led to investigating its feasibility as high-dose-rate seed. In this work, Monte Carlo calculation was performed to obtain dosimetric parameters of 169Yb, Model M42 source at different radial distances according to AAPM TG-43U1 and HEBD Report about HDR sources in both air vacuum a...

2006
RICHARD H. OLSHER

With the advent of inexpensive computing power over the past two decades, applications of Monte Carlo radiation transport techniques have proliferated dramatically. At Los Alamos, the Monte Carlo codes MCNP5 [1] and MCNPX [2] are used routinely on personal computer platforms for radiation shielding analysis and dosimetry calculations. These codes are attractive for such applications because of ...

Journal: :iranian journal of radiation research 0
a. mostaar medical physics department, tehran university of medical sciences, tehran, iran m. allahverdi department of radiotherapy physics, cancer institute, tehran, iran m. shahriari gamma irradiation center, atomic energy organization of iran, tehran, iran

background: in treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by icru in report 24. the experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. therefore, inhomogeneity corrections should be used in treatment pla...

2004
J. T. Moscicki S. Guatelli M. G. Pia M. Piergentili

We show how nowadays it is possible to achieve the goal of accuracy and fast computation response in radiotherapic dosimetry using Monte Carlo methods, together with a distributed computing model. Monte Carlo methods have never been used in clinical practice because, even if they are more accurate than available commercial software, the calculation time needed to accumulate sufficient statistic...

Journal: :iranian journal of radiation research 0
o. kiavar department nuclear engineering, science and research branch, islamic azad university, tehran, iran m. sadeghi agricultural, medical & industrial research school, nuclear science and technology research institute, karaj, iran

background: recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. in this study a unique radioactive source for intra vascular brachytherapy (ivbt) was investigated. the two-dimensional dose distribution in water for a 32p ivbt stent has been calculated. the pure beta emitter source 32p has been coated on p...

Journal: :Medical physics 2013
Jonathan Morin Dominic Beliveau-Nadeau Eunah Chung Jan Seuntjens Dany Theriault Louis Archambault Sam Beddar Luc Beaulieu

PURPOSE Small-field dosimetry is challenging, and the main limitations of most dosimeters are insufficient spatial resolution, water nonequivalence, and energy dependence. The purpose of this study was to compare plastic scintillation detectors (PSDs) to several commercial stereotactic dosimeters by measuring total scatter factors and dose profiles on a CyberKnife system. METHODS Two PSDs wer...

M. Zehtabian, R. Faghihi, S. Sina,

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

J. Novotny Jr., T. Veselsky, V. Pastykova,

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

Background: High-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer.O...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید