نتایج جستجو برای: maximum skin dose

تعداد نتایج: 769272  

2012
Stephen F. Kry Susan A. Smith Rita Weathers Marilyn Stovall

The skin dose associated with radiotherapy may be of interest for clinical evaluation or investigating the risk of late effects. However, skin dose is not intuitive and is difficult to measure. Our objectives were to develop and evaluate a general estimation technique for skin dose based on treatment parameters. The literature on skin dose was supplemented with measurements and Monte Carlo simu...

ژورنال: مجله دندانپزشکی 2011
اسکندرلو, امیر, رحیمی, عزیزاله, رستم پور, نیما, قاضی خانلو ثانی, کریم ,

Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT), conventional and spiral computed tomography (CT).Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TL...

Journal: :Physics in medicine and biology 2011
Andrew Kelly Nicholas Hardcastle Peter Metcalfe Dean Cutajar Alexandra Quinn Kerwyn Foo Michael Cardoso Sheree Barlin Anatoly Rosenfeld

Curative breast radiotherapy typically leaves patients with varying degrees of cosmetic damage. One problem interfering with cosmetically acceptable breast radiotherapy is the external contour for large pendulous breasts which often results in high doses to skin folds. Thermoplastic casts are often employed to secure the breasts to maintain setup reproducibility and limit the presence of skin f...

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2015

2008
Laurence E. Court Roy B. Tishler Aaron M. Allen Hong Xiang Mike Makrigiorgos Lee Chin

This work investigates the accuracy of skin dose calculations using the Eclipse treatment planning system. Skin dose was measured using micro-MOSFETs for a range of irradiation conditions (open fields, physical wedges, dynamic wedges, different SSDs) for 6MV and 10MV beams, and compared with the mean dose calculated to a 2mm thick "skin" structure for semi-cylindrical phantoms (representative o...

Journal: :Physics in medicine and biology 1998
M J Butson P K Yu P E Metcalfe

A radiotheraphy skin dose profile can be obtained with radiochromic film. The central axis skin dose relative to Dmax for a 10 x 10 cm2 field size was found to be 22%, 17% and 15.5% for 6 MV, 10 MV and 18 MV photon beams. Peripheral dose increased with increasing field size. At 10 MV the skin dose 2 cm outside the geometric field edge was measured as 6%, 10% and 17% for 10 x 10 cm2, 20 x 20 cm2...

Journal: :Journal of immunology 1970
S S Stefani C D Moore

Single or repetitive i.p. injections of Phytohemagglutinin (PHA) induced a selective marked decrease in blood and bone marrow lymphocytes in mice, suggesting that PHA might have a specific immunosuppressive effect. To test this hypothesis, parallel' experiments were conducted using female C57Bl/6J (H-2b) mice as recipients and either female C3H/HeJ (H-2k) or female (C57Blx C3He) Fl (H-2b,k) hyb...

Journal: :journal of biomedical physics and engineering 0
s sina radiation research center, shiraz university, shiraz, iran b zeinali m karimipoorfard f lotfalizadeh m sadeghi e zamani

background: dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. objective: the aim of this study is to obtain the entrance skin dose (esd) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters tld-100 (lif: mg, ti) and gr-200 (lif: mg, cu, p) and also to obtain the a...

Journal: :Medical physics 2012
G Zhang K Javedan E Moros K Latifi V Feygelman H Lee Moffitt

PURPOSE Flattening filter free (FFF) beams in radiotherapy have advantages such as shorter treatment delivery time and lower out-of-field dose compared with conventional flattened beams. This study investigates in detail the skin dose induced by FFF beams from a TrueBeam accelerator (Varian Medical Systems, Palo Alto, CA) using Monte Carlo method. METHODS Phase space files generated using rea...

Journal: :Health physics 2007
Hiroko Ohuchi Toshimitsu Satoh Yoichi Eguchi Yuji Kaga Takeshi Arai Shin-ichi Suzuki Akira Yamadera

A method using europium-doped BaFBr imaging plates (IPs) has been developed to estimate and map values of entrance skin doses during interventional radiology (IR). IPs offer many advantages for measuring the entrance skin dose because they have a wide dynamic range (up to 100 Gy), provide high spatial resolution as a detector of two-dimensional images, and can be used repeatedly. The entrance s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید