نتایج جستجو برای: iol calculation

تعداد نتایج: 103883  

2013
Ejaz Ansari

To assess whether the intraocular pressure (IOP) in selective laser trabeculoplasty (SLT)-treated eyes is maintained following subsequent phacoemulsification and lens implant (phaco + IOL). Retrospective single center review of 45 eyes of 35 patients who had open angle glaucoma (OAG), successfully treated by SLT by the same surgeon (EA), and then had routine phaco + IOL by same surgeon (EA). Th...

2010
Farid Karimian Mohammad-Mehdi Sadoughi

Endothelial keratoplasty (EK) is the most exciting recent development in corneal transplantation. It has experienced surprisingly rapid growth in a very short period of time. One of the indications for EK is pseudophakic bullous keratopathy. However, concomitant intraocular lens (IOL) exchange, if indicated, may prove challenging. Some surgeons routinely perform IOL exchange with a scleral-fixa...

Journal: :Journal of the College of Physicians and Surgeons--Pakistan : JCPSP 2005
Yezhen Yang Manqiang Peng Yiqin Duan Xuetao Huang Kuanshu Li Ding Lin

Opacification of a hydrophilic acrylic intraocular (IOL) lens is a rare phenomenon. We herein report a case of a 57-year man complaining of decreased vision at left eye for the last 4 months. He had undergone phacoemulsification with IOL implantation 2 years back. IOL opacification was observed through slit-lamp. IOL exchange was carried out. The exchanged IOL and a new lens of the same model w...

2016
Sung In Kim Kiseok Kim

PURPOSE To report a new technique using tram-track suture for pupillary capture of a scleral fixated posterior chamber intraocular lens (PC-IOL) to reposition the tilted IOL. METHODS In this prospective interventional case series, we describe a tram-track suture for pupillary capture of a scleral fixated PC-IOL. A long straight needle with double-armed 10-0 polypropylene is passed behind the ...

Journal: :Journal of refractive surgery 2015
Ruth Lapid-Gortzak Grzegorz Labuz Ivanka J van der Meulen Jan Willem van der Linden M P Mourits Tom J van den Berg

PURPOSE To evaluate differences in straylight between eyes implanted with a hydrophilic multifocal IOL (Seelens MF; Hanita Lenses, Hanita, Israel) and a hydrophobic multifocal IOL (SN6AD1; Alcon Laboratories, Inc., Fort Worth, TX). METHODS In a prospective cohort study, routinely obtained straylight measurements (C-Quant; Oculus Optikgeräte, Wetzlar, Germany) 3 months after standard phacoemul...

2017
Bence L Kolozsvári Gergely Losonczy Dorottya Pásztor Mariann Fodor

BACKGROUND Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are awa...

Journal: :Journal of refractive surgery 2013
Amar Agarwal Athiya Agarwal Soosan Jacob Priya Narang

Glued intrascleral fi xation is a technique aimed at restoring pseudophakia in patients with posterior capsular dehiscence and represents the theme of fi xing the haptics into the scleral pockets to allow long-term stability with no decentration and tilt.1,2 The technique has evolved from the use of polymethylmethacrylate nonfoldable intraocular lenses (IOLs) to the application of modern three-...

Journal: :Journal of The Korean Ophthalmological Society 2022

Purpose: To compare the clinical outcomes of cataract surgery using ARTIS ® PL E (Cristalens Industrie, Lannion, France) intraocular lens (IOL) and conventional Tecnis ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA) IOL.Methods: This retrospective study examined patients who underwent in-the-bag implantation either an (33 eyes, group A) or (45 B) IOL after phacoemulsification performed...

Journal: :Journal of refractive surgery 2013
Ana Paula Canto Priyanka Chhadva Florence Cabot Anat Galor Sonia H Yoo Pravin K Vaddavalli William W Culbertson

PURPOSE To compare preoperative methods for calculating intraocular lens (IOL) power versus the intraoperative wavefront aberrometer in eyes with a history of refractive surgery. METHODS A retrospective study of 46 eyes (33 patients) with previous refractive surgery that underwent subsequent cataract surgery was conducted. Suggested IOL power predicted by ORange intraoperative wavefront aberr...

Journal: :Survey of ophthalmology 1998
A N Carlson W C Stewart P C Tso

Intraocular lens (IOL)-related complications are caused primarily by mechanical trauma, inflammatory or infectious complications, or optical problems. Complications may occur at the time of surgery or be the result of an ongoing postoperative process. Mechanical and inflammatory injury may produce corneal decompensation, cystoid macular edema, hyphema, uveitis, and glaucoma, causing reduced vis...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید