نتایج جستجو برای: intensity modulated radiotherapy
تعداد نتایج: 290062 فیلتر نتایج به سال:
145 This work has supported by the Yeungnam University Academic Research Fund (210A054024). Submitted August, 13, 2013, Accepted September, 6, 2013 Corresponding Author: Ji Woon Yea, Department of Radiation Oncology, Yeungnam University Medical Center, 317-1, Daemeyoungdong, Nam-gu, Daegu 705-717, Korea Tel: 053)620-3371, Fax: 053)624-3599 E-mail: [email protected] Comparison of IMRT and VMAT T...
Small photon field used in the intensity modulated radiotherapy (IMRT) and stereotactic radio surgery (SRS). It is difficult to measure beam profile and output factor because of electron disequilibrium, partial shutting of source because of this challenges, we need the good detector. This article is collection of 5 or more article and summary of the results of EBT3 that compared with EBT2 film ...
We performed an initial dosimetric evaluation of SmartArc - a novel VMAT planning module for Philips Pinnacle treatment planning system. A test suite of structure sets and dose objectives provided by the AAPM for multi-institutional comparison of IMRT dosimetry was used. A total of fifty plans were successfully delivered. The effect of control point spacing on dosimetric accuracy was investigat...
Seven years of experience in compensator intensity-modulated radiotherapy (IMRT) clinical implementation are presented. An inverse planning dose optimization algorithm was used to generate intensity modulation maps, which were delivered via either the compensator or segmental multileaf collimator (MLC) IMRT techniques. The in-house developed compensator-IMRT technique is presented with the focu...
Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...
PURPOSE The most common material for shielding is concrete, which can be made using various materials of different densities as aggregates. New techniques in radiotherapy, as IMRT and VMAT, require more monitor units and it is important to develop specifically designed shielding materials. METHODS Arraela S.L. has developed new concrete (CONTEK®-RFH2), which is made from an arid with a high p...
Arc-modulated radiation therapy (AMRT) is a novel rotational intensitymodulated radiation therapy (IMRT) technique developed for a clinical linear accelerator that aims to deliver highly conformal radiation treatment using just one arc of gantry rotation. Compared to fixed-gantry IMRT and the multiplearc intensity-modulated arc therapy (IMAT) techniques, AMRT promises the same treatment quality...
This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and sta...
The first aim of the present study was to investigate the feasibility of using fewer beam angles to improve delivery efficiency for the treatment of oropharyngeal cancer (OPC) with inverse-planned intensity-modulated radiation therapy (IP-IMRT). A secondary aim was to evaluate whether the simplified IP-IMRT plans could reduce the indirect radiation dose. The treatment plans for 5 consecutive OP...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید