نتایج جستجو برای: in vivo fertility

تعداد نتایج: 16988718  

2015
Claire E. J. Cheetham Bryce D. Grier Leonardo Belluscio

The ability to label and manipulate specific cell types is central to understanding the structure and function of neuronal circuits. Here, we have developed a simple, affordable strategy for labeling of genetically defined populations of neurons throughout a targeted brain region: Bulk Regional Viral Injection (BReVI). Our strategy involves a large volume adeno-associated virus (AAV) injection ...

2016
Kristen M. Grinstead Laura Rowe Charles M. Ensor Smita Joel Pirouz Daftarian Emre Dikici Jean-Marc Zingg Sylvia Daunert

The increased importance of in vivo diagnostics has posed new demands for imaging technologies. In that regard, there is a need for imaging molecules capable of expanding the applications of current state-of-the-art imaging in vivo diagnostics. To that end, there is a desire for new reporter molecules capable of providing strong signals, are non-toxic, and can be tailored to diagnose or monitor...

Journal: :Nature communications 2013
Andreas Grönlund Per Lötstedt Johan Elf

Negative autoregulation, where a transcription factor regulates its own expression by preventing transcription, is commonly used to suppress fluctuations in gene expression. Recent single molecule in vivo imaging has shown that it takes significant time for a transcription factor molecule to bind its chromosomal binding site. Given the slow association kinetics, transcription factor mediated fe...

2012
Liqin Cao Satoru Kobayakawa Atsushi Yoshiki Kuniya Abe

Intravital imaging of brain and bone marrow cells in the skull with subcellular resolution has revolutionized neurobiology, immunology and hematology. However, the application of this powerful technology in studies of abdominal organs has long been impeded by organ motion caused by breathing and heartbeat. Here we describe for the first time a simple device designated 'microstage' that effectiv...

Journal: :Magnetic resonance in medicine 2014
Huajun She Rong-Rong Chen Dong Liang Edward V R DiBella Leslie Ying

PURPOSE To develop a sensitivity-based parallel imaging reconstruction method to reconstruct iteratively both the coil sensitivities and MR image simultaneously based on their prior information. METHODS Parallel magnetic resonance imaging reconstruction problem can be formulated as a multichannel sampling problem where solutions are sought analytically. However, the channel functions given by...

2013
Jonathan J. Liu Ireneusz Grulkowski Martin F. Kraus Benjamin Potsaid Chen D. Lu Bernhard Baumann Jay S. Duker Joachim Hornegger James G. Fujimoto

Swept source/Fourier domain OCT is demonstrated for in vivo imaging of the rodent eye. Using commercial swept laser technology, we developed a prototype OCT imaging system for small animal ocular imaging operating in the 1050 nm wavelength range at an axial scan rate of 100 kHz with ~6 µm axial resolution. The high imaging speed enables volumetric imaging with high axial scan densities, measuri...

Journal: :Magnetic resonance in medicine 2018
Sebastian Weingärtner Chetan Shenoy Benedikt Rieger Lothar R Schad Jeanette Schulz-Menger Mehmet Akçakaya

PURPOSE To develop and evaluate a cardiac phase-resolved myocardial T1 mapping sequence. METHODS The proposed method for temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ) is based on contiguous fast low-angle shot imaging readout after magnetization inversion from the pulsed steady state. Thereby, segmented k-space data are acquired over multiple heartbeats, before...

2013
Issa Ibraheem

This paper proposes a novel approach for the automatic detection of allergy test (allergy lesion). A hyperspectral microscope system was used to image the test samples which were diagnosed by dermatologist. It was found that allergy of different levels, and healthy skin cells show absorption spectra, which are sufficiently characteristic and yet reproducible enough to allow for differentiation ...

Journal: :Journal of biomedical optics 2011
Tong Wu Zhihua Ding Chuan Wang Minghui Chen

A high speed swept source optical coherence tomography (SS-OCT) system capable of full-range imaging is presented. Wave-number carrier frequency is introduced into the spectral interference signal by a transmissive dispersive optical delay line (TDODL). High carrier frequency in the spectral interference signal corresponding to an equivalent distance-shift is exploited to obtain full-range OCT ...

2017

Photoacoustic Computed Microscopy (PACM) is a new label-free microscopic method that combines current photoacoustic microscopy technique with a modelbased inverse reconstruction algorithm to provide functional images of microvasculature. This article demonstrates its in vivo imaging ability of quantifying important functional parameters at the small vessel level in a rodent model. This new tech...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید