نتایج جستجو برای: immunoassays

تعداد نتایج: 5308  

Journal: :caspian journal of internal medicine 0
faranak kazerouni houshang amirrasouli

background: since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. we performed an analytical evaluation of the new electrochemiluminescent immunoassay (eclia) for serum tsh, ft4 and t3 in the elecsys 2010 immunoassay system and compared the resu...

Journal: :Clinical chemistry 2007
Rémy Sapin

Read more and get great! That's what the book enPDFd insulin immunoassays fast approaching 50 years of existence and still calling for standardization ed will give for every reader to read this book. This is an on-line book provided in this website. Even this book becomes a choice of someone to read, many in the world also loves it so much. As what we talk, when you read more every page of this...

Journal: :CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne 2011
Michael L Rekart Josephine Macintosh

Third-generation enzyme immunoassays start to de tect anti-HIV antibodies within 20–22 days after exposure; fourthgeneration enzyme immunoassays, which test for p24 antigen and anti-HIV antibodies, can yield positive re sults within 16–18 days. RNA nucleic acid amplification testing starts to de tect HIV infection within 7–14 days. At $75 per test, these RNA tests are too costly for routine use...

1998
James R. Hagler

Five different immunoassay formats were examined for their ability to detect a minute quantity of prey remains in predator guts. The convergent lady beetle, Hippodamia convergens Guérin-Meneville, that had consumed either one or five pink bollworm, Pectinophora gossypiella (Saunders), eggs was evaluated by the following immunoassays: three variations of enzyme-linked immunosorbent assay (ELISA)...

Journal: :Analytical biochemistry 2000
P Arenkov A Kukhtin A Gemmell S Voloshchuk V Chupeeva A Mirzabekov

Different proteins such as antibodies, antigens, and enzymes were immobilized within the 100 x 100 x 20-microm gel pads of protein microchips. A modified polyacrylamide gel has been developed to accommodate proteins of a size up to 400,000 daltons. Electrophoresis in the microchip reaction chamber speeded up antigen-antibody interactions within the gel. Protein microchips were used in immunoass...

2009
Il-Hoon Cho Sung-Min Seo Jin-Woo Jeon Se-Hwan Paek

The enhanced analytical performances of immunoassays that employed site-directly immobilized antibodies as the capture binders have been functionally characterized in terms of antigen-antibody complex formation on solid surfaces. Three antibody species specific to cardiac troponin I, immunoglobulin G (IgG), Fab, and F(ab')(2) were site-directly biotinylated within the hinge region and then immo...

Journal: :Electrophoresis 2001
J Taylor G Picelli D J Harrison

Using a high-affinity antibody for estradiol, thermodynamic and experimental limitations on detection limits for competitive capillary electrophoretic immunoassays were examined. Theoretical modeling of the dose-response curves for such assays allowed for optimization of experimental conditions. Through the examination of experimental and theoretical results generalizations could be made as to ...

Journal: :Clinical chemistry 1991
A Larsson A Karlsson-Parra J Sjöquist

Rheumatoid factor (RF) is a major source of interference in many immunoassays. Most immunoassays use mammalian polyclonal or monoclonal antibodies, and RF can react with IgG from mammalian species, thus causing false-positive results. In this work we have studied RF interference in a sandwich ELISA, where RF in the sample may react with both the capture antibody and the detection antibody to gi...

Journal: :Clinical chemistry and laboratory medicine 2012
Caroline Le Goff Stéphanie Peeters Yannick Crine Pierre Lukas Jean-Claude Souberbielle Etienne Cavalier

Introduction: In serum, 25-hydroxy-vitamin D (25(OH)D) can be found in two forms, namely 25(OH)D2 and 25(OH)D3. We recently published a mathematical method to estimate the 25(OH)D2 recovery without spiking the samples. Since then, new “total” vitamin D immunoassays have appeared on the market (Roche “Total” vitamin D, Siemens Centaur vitamin D “total”, “total” vitamin D on DiaSorin Liaison XL, ...

Journal: :Clinical chemistry 1998
I T Ocal T R Green

We have reevaluated the feasibility of using direct immunochemical methods to track free digoxin in patients receiving Digibind. We report here that results obtained by the Stratus II and AxSYM immunoassays on patients receiving digoxin (without Digibind), digoxin-fortified serum samples supplemented with Digibind, and a digitoxic patient treated with Digibind, show no clinically significant bi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید