In order to provide automatic IMRT dose delivery with an add-on MMLC a technical integration of a MMLC system with a linear accelerator was realized. The principle of this integration and the changes and enhancements of the existing hard- and software are briefly described. The system was tested by the automatic delivery of an IMRT plan designed for a head and neck phantom. A verification of do...
PURPOSE To establish a film dosimetric method for high-resolution measurement in the dose build-up region. METHODS Percent depth dose (PDD) curves were measured in water for TomoTherapy using Gafchromic EBT2 films. Depth dose measurements were also performed using Standard Imaging A1SL and PTW PinPoint ionization chambers, as well as a PTW DiodeE detector. The film and detector measurements w...
The visible absorption spectra of Radiachromic FWT-60 radiochromic film have been investigated to analyse the dosimetry characteristics of the film. The film is radiation sensitive to high absorbed doses. The visible absorption spectra of this film when exposed to photon radiation show a peak at 605 nm which is stable over the dose range of 0 Gy to 20 kGy. The radiation sensitive absorption spe...
Purpose Radiochromic film has been established as a detector that can be used without the need for perturbation correction factors small field dosimetry in water. However, low density media such lung have yet to published. This study calculated required account of radiochromic when equivalent material. Method Monte Carlo simulations were calculate dose Gafchromic EBT3 placed inside phantom. The...
To report a study of the use of GAFCHROMIC EBT radiochromic film (RCF) digitized with a commercially available flatbed document scanner for accurate and reliable all-purpose two-dimensional (2D) absolute dosimetry within a clinical environment. We used a simplified methodology that yields high-precision dosimetry measurements without significant postirradiation correction. The Epson Expression ...
EBT2 film is widely used for quality assurance in radiation therapy. The purpose of this study was to investigate the homogeneity of EBT2 film among various lots, and the dose dependence of heterogeneity. EBT2 film was positioned in the center of a flatbed scanner and scanned in transmission mode at 75 dpi. Homogeneity was investigated by evaluating gray value and net optical density (netOD) wi...
Lack of underlying material can lead to dose reduction in kilovoltage radiotherapy treatments because of backscatter reduction. Conversely, the use of lead shielding can lead to large dose enhancement close to the lead interface. GAFCHROMIC film has been shown to be of use in verification of local backscatter factors compared to reference data in codes of practice, but careful handling and mult...