نتایج جستجو برای: cortisol concentration

تعداد نتایج: 398550  

Journal: :Journal of clinical pathology 1991
G H Mills R D Ellis P R Beck

A 60 year old man with panhypopituitarism due to a large meningioma and prolonged and exaggerated thyroid stimulating hormone (TSH) responses is described. Initial investigations showed a subnormal urinary free cortisol concentration, a low serum cortisol taken at 0900 hours, and a low free T4 concentration. The TSH was towards the upper end of the normal range. Subsequently pituitary function ...

Journal: :Life sciences 2003
Kerstin Persson Waye Angela Clow Sue Edwards Frank Hucklebridge Ragnar Rylander

The effects of night-time exposure to traffic noise (TN) or low frequency noise (LFN) on the cortisol awakening response and subjective sleep quality were determined. Twelve male subjects slept for five consecutive nights in a noise-sleep laboratory. After one night of acclimatisation and one reference night, subjects were exposed to either TN (35dB L(Aeq), 50dB L(Amax)) or LFN (40dB L(Aeq)) on...

2017
Kelly Doolin Chloe Farrell Leonardo Tozzi Andrew Harkin Thomas Frodl Veronica O'Keane

Dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis and inflammatory systems is a consistent finding in patients with Major Depressive Disorder (MDD). Cortisol is often assessed by measurement of the cortisol awakening response (CAR) and/or diurnal cortisol levels. Some methods of cortisol measurement overestimate cortisol concentration due to detection of other glucocorticoids inclu...

2011
Il-young Shin Ryun-sup Ahn Sae-il Chun Young-jin Lee Min-soo Kim Chea-kwan Lee Simon Sung

PURPOSE Cortisol awakening response (CAR) and nighttime cortisol levels have been used as indices of adrenocortical activity. However, population-based statistical information regarding these indices has not been provided in healthy subjects. This study was carried out to provide basic statistical information regarding these indices. MATERIALS AND METHODS Cortisol levels were measured in sali...

Journal: :Circulation 1976
K M Taylor J V Jones M S Walker S Rao W H Bain

The response patterns of plasma cortisol and plasma free cortisol have been studied in 20 consecutive patients undergoing cardiac surgery involving the use of heart-lung bypass. Sixteen consecutive patients undergoing closed mitral valvotomy have been used as controls. Total plasma cortisol levels fell at the onset of extracorporeal circulation (ECC) and did not rise significantly throughout th...

Journal: :Clinical endocrinology 2004
Peak M Mah Richard C Jenkins Amin Rostami-Hodjegan John Newell-Price Anita Doane Victoria Ibbotson Geoffrey T Tucker Richard J Ross

OBJECTIVE The objective of this study was to examine the variables determining hydrocortisone (HC) disposition in patients with adrenal insufficiency and to develop practical protocols for individualized prescribing and monitoring of HC treatment. DESIGN AND PATIENTS Serum cortisol profiles were measured in 20 cortisol-insufficient patients (09.00 h cortisol < 50 nmol/l) given oral HC as eith...

Journal: :European journal of endocrinology 2014
R A Alwani L W Schmit Jongbloed F H de Jong A J van der Lely W W de Herder R A Feelders

OBJECTIVE To evaluate the diagnostic performance of four different tests in order to differentiate between Cushing's disease (CD) and pseudo-Cushing's syndrome (PCS). METHODS In this prospective study, a total of 73 patients with clinical features of hypercortisolism and insufficient suppression of serum cortisol after 1 mg overnight dexamethasone and/or an elevated excretion of cortisol in 2...

2014
Yusuke Tahara Zhe Huang Tetsuro Kiritoshi Takeshi Onodera Kiyoshi Toko

The monitoring of salivary cortisol as a key biomarker of an individual's stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assem...

2004
Ellen Jensen Charles E. Wood Maureen Keller-Wood

Jensen, Ellen, Charles E. Wood, and Maureen Keller-Wood. Chronic alterations in ovine maternal corticosteroid levels influence uterine blood flow and placental and fetal growth. Am J Physiol Regul Integr Comp Physiol 288: R54–R61, 2005. First published July 1, 2004; doi:10.1152/ajpregu.00149.2004.—Previous work from this laboratory demonstrated that the elevation of maternal plasma corticostero...

Journal: :Annals of clinical and laboratory science 1980
R Valdes M R Wills J Savory

The performance characteristics are reported for a serum cortisol assay using the GAMMAFLO Automated Assay System, an automated continuous-flow system for radioimmunoassay (RIA). This automated system utilizes a combination of continuous-flow methodology and column chromatography techniques. The cortisol assay studied had a standard curve range of 10.0 to 500 microgram per L. The intra-assay an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید