نتایج جستجو برای: cooling systems
تعداد نتایج: 1229710 فیلتر نتایج به سال:
This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...
For more than a decade, cold atoms represented weakly interacting systems. Laser cooling achieved temperatures typically around 100 μK in a classical gas, far away from quantum degeneracy. Evaporative cooling led to Bose-Einstein condensation at temperatures typically around 100 nK. Bose-Einstein condensates are weakly interacting many-body systems described by mean field physics through the Gr...
Water spray cooling is a technique typically used in heat treatment and other metallurgical processes where controlled temperature regimes are required. Water spray cooling is used in static (without movement) or dynamic (with movement of the steel plate) regimes. The static regime is notable for the fixed position of the hot steel plate and fixed spray nozzle. This regime is typical for quench...
The interplay between dissipation and long-range repulsive/attractive forces in homogeneous, dilute, mono-disperse particle systems is studied. The pseudo-Liouville operator formalism, originally introduced for hard-sphere interactions, is modified such that it provides very good predictions for systems with weak long-range forces at low densities, with the ratio of potential to fluctuation kin...
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating a re-thinking about the most effective cooling systems for the future beyond conventional air cooling of the chips/servers. A potential signi...
Demonstration of Solar Heating and Cooling System using Sorption Integrated Solar Thermal Collectors
Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a sola...
run-out-table (rot) is located between last finishing stand and down coiler in a hot strip mill. as the hot steel strip passes from rot, water jets impact on it from top and bottom and strip temperature decreases approximately from 800-950 °c to 500-750°c. the temperature history that strip experience while passing through rot affects significantly the metallurgical and mechanical properties, s...
The power dissipation levels in high performance personal computers continue to increase rapidly while the silicon die temperature requirements remain unchanged or have been lowered. Advanced air cooling solutions for the major heat sources such as CPU and GPU modules use heat pipes and high flow rate fans to manage the heat load at the expense of significant increases in the sound power emitte...
A detailed modular modeling of an absorbent cooling system is presented in this paper. The model including the key components is described in terms of design parameters, inputs, control variables, and outputs. The model is used to simulate the operating conditions for estimating the behavior of individual components and system performance, and to conduct a sensitivity analysis based on the give...
The ever-increasing operational cost of geographically distributed datacenters has become a critical issue for cloud service providers. In order to cut the electricity cost of geographically distributed datacenters, several workload management schemes have been proposed, such as Electricity price-aware InteR-datacenter load balancing (EIR), which reduces the electricity cost of active servers b...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید