A recently described (Clin Chim Acta 127: 87-95, 1982) colorimetric assay for glycated proteins in serum exploits their ketoamine activity to reduce 3,3'-(3,3'-dimethoxy-4,4'-biphenylylene)bis [2-(p-nitrophenyl)-5-phenyl-2H-tetrazolium chloride] (nitroblue tetrazolium) in alkaline solution; the authors termed this the "fructosamine assay." The method is simple, requiring only the addition of on...
Fe-doped titanite (TiCaSiO5) and quasi-titanite (Ti0.5CaSi1.5O5) compositions were synthesized by the ceramic method. For each structure, two samples with 0.1 mol% and 0.2 mol% Fe were used. The synthesized samples were homogenized using a planetary ball mill in 2-ethylhexyl stearate solvent and then printed on the ceramic with screen printing system....
Ascorbic acid was measured in 125 plasma samples by an automated colorimetric method involving dichlorophenolindophenol and by a "high-performance" liquid-chromatographic procedure with electrochemical detection. The two methods gave comparable results for samples with ascorbate concentrations of 1 to 20 mg/L (r = 0.97). We also measured the amount of total ascorbate (ascorbic acid + dehydroasc...
This paper describes a computational model based on CIELAB colorimetry and full tonal scale evaluation to define objective boundary conditions for “Retained Image Appearance” in a photograph where 100% retention equates to no visual change and 0% retention means total functional loss of image information content. The “Retained Image Appearance” model, I*, examines the color information (hue and...
Photoelectric Colorimetry of Platinum as Derivative of Phenylthiosemicarbazide by Extraction Method.
The mechanical properties of ceramic injection molded (CIM) components are largely influenced by microstructural inhomogeneities that result from the interaction of rheological properties of the thermoplastic feedstock with machine parameters and the design of mold and injection gate. These inhomogeneities (e. g. texture, turbulences, joints, and density gradients) can form weak spots in the ma...
The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...