نتایج جستجو برای: circular composite tube

تعداد نتایج: 282533  

A. Ghorbanpour Arani E. Haghparast S. Amir Z. Khoddami Maraghi

In this research, static stresses analysis of boron nitride nano - tube reinforced composite (BNNTRC) cylinder made of poly - vinylidene fluoride (PVDF) subjected to non - axisymmetric thermo - mechanical loads and applied voltage is developed. The surrounded elastic medium is modelled by Pasternak foundation. Composite structure is modeled based on piezoelectric fiber reinforced composite (PFR...

2015
Yungang Wang Heng Chen Zhongya Chen Haidong Ma Mehrdad Massoudi

The slagging and fouling characteristics of the heat recovery steam generator (HRSG) for ferrosilicon electric furnaces are discussed in this paper. Three ash samples were taken from the HRSG of a ferrosilicon furnace in Ningxia Province, China, which suffered from serious slagging and fouling. X-ray fluorescence (XRF), X-ray powder diffraction (XRD) and scanning electron microscope (SEM) were ...

2008
C. Tort J. F. Hajjar

This paper presents a computational study assessing the seismic response of rectangular concrete-filled steel tube (RCFT) members and frames to develop a reliability-based performance-based design methodology. A new analysis formulation was derived based on a mixed-finite element approach allowing geometrically and materially nonlinear analysis of RCFT frames under seismic and non-seismic loadi...

2017
A. Daly S. Evans C. Ashmore S. Chahal S. Santra A. MacDonald

Children with inherited metabolic disorders (IMD) who are dependent on tube feeding and require a protein restriction are commonly fed by 'modular tube feeds' consisting of several ingredients. A longitudinal, prospective two-phase study, conducted over 18 months assessed the long-term efficacy of a pre-measured protein-free composite feed. This was specifically designed to meet the non-protein...

2014
Erik Smistad Reidar Brekken Frank Lindseth

Tube detection filters (TDFs) are useful for segmentation and centerline extraction of tubular structures such as blood vessels and airways in medical images. Most TDFs assume that the cross-sectional profile of the tubular structure is circular. This assumption is not always correct, for instance in the case of abdominal aortic aneurysms (AAAs). Another problem with several TDFs is that they g...

2008
Y. Zhu R. W. Ogden

In this paper, we consider bifurcation from a circular cylindrical deformed configuration of a thick-walled circular cylindrical tube of incompressible isotropic elastic material subject to combined axial loading and external pressure. In particular, we examine both axisymmetric and asymmetric modes of bifurcation. The analysis is based on the three-dimensional incremental equilibrium equations...

Journal: :Water research 2009
Robert N Meroney P E Colorado

Computational Fluid Dynamics (CFD) was used to simulate the mixing characteristics of four different circular anaerobic digester tanks (diameters of 13.7, 21.3, 30.5, and 33.5m) equipped with single and multiple draft impeller tube mixers. Rates of mixing of step and slug injection of tracers were calculated from which digester volume turnover time (DVTT), mixture diffusion time (MDT), and hydr...

2008
Cenk Tort Jerome F. Hajjar

A comprehensive computational model to simulate the nonlinear seismic response of composite frames with rectangular concrete-filled steel tube (RCFT) beam-columns and steel girders and braces is presented in this work. A three-dimensional fiber-based distributed plasticity mixed finite element formulation is introduced. The finite element formulation of RCFT beam-columns was derived with separa...

2009
C. K. Cheung B. M. Liaw B. B. Raju

A series of tensile experiments were performed on S2 glass/toughened epoxy composite strips with a center hole or a pin joint at various temperatures within the range of −60C and 125C. Four different lay-up configurations each of 24 layers: [0°], [0°/90°], [45°/−45°] and [0°/45°/90°/−45°] and four different hole diameters: 1/8”, 1/4”, 3/8”, 1/2” were used in both types of specimens. For certain...

2004
Lotfi Toubal Moussa Karama Bernard Lorrain

A non-contact measurement method, namely electronic speckle pattern interferometer (ESPI), was used to investigate the tensile strain field of a composites plate in the presence of stress concentrations caused by a geometrical defect consisting of circular hole. ESPI uses the principle of 3D speckle interferometry to measure the deformation and contour of the measuring field with submicrometer ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید