نتایج جستجو برای: absorption refrigeration

تعداد نتایج: 136399  

2015
Xukai Yang Shengchun Liu X. K. Yang S. C. Liu

In the present study, the ice slurry refrigeration system with pre-cooling heat exchanger (ISSH) is studied experimentally to achieve the system performance, ice crystal formation time and the temperature of ice crystal formation. The operating parameters considered in this paper include the concentration of salt solution, suction pressure, discharge pressure and Energy Efficiency Ratio (EER). ...

2012
Isam A. Mohamed Ahmed

This work describes refrigeration effects during storage on total protein and amino acids composition of raw and processed flour of two pearl millet cultivars (Ashana and Dembi). The protein content of the whole raw flour was found to be 14.46 and 13.38% for Ashana and Dembi cultivars, respectively. Dehulling of the grains reduced the protein content to 13.38 and 12.67% for the cultivars, respe...

2012
D. Sendil Kumar R. Elansezhian Ching-Song Jwo

In this paper, an experimental work was investigated on nanorefrigerant .Nano Al2O3-PAG oil was used as nano-refrigerant in R134a vapour compression refrigeration system . An experimental setup was designed and fabricated in the lab. The system performance was investigated using energy consumption test and freeze capacity test. The results indicate that Al2O3 nano refrigerant works normally and...

2009
Thomas J. Leck

In response to concerns about the contribution of fluorocarbon refrigerants to global climate change, a new, more environmentally sustainable, refrigerant molecule has been developed and is being evaluated. This new molecule is the hydrofluoroolefin 2,3,3,3,-tetrafluoroprop-1-ene, or HFO-1234yf. The molecule has been shown to be stable inside refrigeration equipment, but to quickly decompose if...

2015
Sílvia A. Moreira Pedro A. R. Fernandes Ricardo Duarte Diana I. Santos Liliana G. Fidalgo Mauro D. Santos Rui P. Queirós Ivonne Delgadillo Jorge A. Saraiva

Hyperbaric storage (HS), storage under pressure at 25°C and 30°C, of a ready-to-eat (RTE) soup was studied and compared with refrigeration. Soup was stored at different time (4 and 8 h), temperature (4°C, 25°C, and 30°C), and pressure (0.1, 100, and 150 MPa) conditions, to compare microbial loads and physicochemical parameters. HS resulted in similar (microbial growth inhibition) to better (mic...

2014
Gourav Patel Sharad Chaudhary

Since long time, it has been noticed that refrigerators are the devices which work almost 365 days round the clock; hence objective of energy efficiency improvement attracts much. There are several ways of improving the performance of a vapor compression refrigeration cycle. Use of an ejector as expansion device is one of the alternative way. The advent of new component ‘Ejector’ into refrigera...

2014
M. Fukuta K. Sawai

A suction line of a refrigeration cycle with vertical upward flow is one area where the refrigeration oil tends to accumulate. This paper discusses the flow characteristics of the oil film in a pipe with the vertical upward flow. Air and oil two-phase flow is used as the first step of the study and the flow pattern of the oil film in the vertical upward flow is observed. The oil film thickness ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید