Journal: :Journal of endodontics 2014
Ismail Davut Capar Hakan Arslan Merve Akcay Huseyin Ertas

INTRODUCTION The purpose of this study was to compare the in vitro amount of apically extruded debris with new endodontic rotary nickel-titanium instruments. METHODS Sixty mandibular premolars were instrumented up to size 25 using ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and HyFlex (Co...

2015
Luigi Tocci Gianluca Plotino Dina Al-Sudani Alessio Giansiracusa Rubini Gianpaolo Sannino Lucila Piasecki Ermanno Putortì Luca Testarelli Gianluca Gambarini

OBJECTIVES The aim of the present study was to evaluate the cutting efficiency of two new reciprocating instruments, Twisted File Adaptive and WaveOne Primary. MATERIAL AND METHODS 10 new Twisted File Adaptive (TF Adaptive) (SybronEndo, Glendora, CA, USA) and 10 new WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland) were activated using a torque-controlled motor, respectively...

2012
David Uroz-Torres María Paloma González-Rodríguez Carmen María Ferrer-Luque

Objective: To compare the straightening of root canal curvature, the apical transportation, the loss of working length and the working time using two rotary systems. Study design: Sixty buccal root canals with angles of curvature between 30 to 99o were instrumented with Mtwo and Twisted File rotary instruments. A series of preand post-operative radiographs were superimposed to determine the str...

Journal: :Journal of endodontics 2015
Sevinç Aktemur Türker Emel Uzunoğlu Mehtap Hülya Aslan

INTRODUCTION The aim of this in vitro study was to evaluate the amount of apically extruded bacteria associated with several root canal preparation systems. METHODS Forty-four extracted human mandibular premolar root canals were contaminated with an Enterococcus faecalis suspension. After incubation at 37°C for 24 hours, the root canals were instrumented using the Twisted File (SybronEndo, Or...

Journal: :Journal of clinical and diagnostic research : JCDR 2015
Gaurav Sharma Pooja Kakkar Asit Vats

OBJECTIVE The objective of this study was to compare the smear layer formed on root canal walls during canal preparation of extracted human teeth by Twisted, Mtwo, and ProTaper rotary nickel titanium instruments. MATERIALS AND METHODS Sixty single rooted human premolar teeth with root curvature <25(0) were selected and randomly divided into three Groups (n= 20 teeth per Group). Three types of...

2016
Reid Wycoff Reid C. Wycoff Sushant Mahajan Erik DeYoung

A COMPARISON OF TORSIONAL STRESS PROPERTIES OF THREE DIFFERENT NICKEL-TITANIUM FILES WITH SIMILAR CROSS-SECTIONAL DESIGN Reid C. Wycoff D.D.S. Marquette University, 2012 The purpose of this study was to compare the in vitro torsional stress characteristics of Twisted Files (SybronEndo, Orange, CA) with two milled files of similar cross section, EndoSequence (Brasseler USA, Savannah, GA) and Pro...

Journal: :Journal of Dental Rehabilitation and Applied Science 2019

Journal: :JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH 2014

Raghubansha Singh Saroj Padhi, Satish Agrawal

In the present work an attempt has been made to study the effect of the twisted tapes as bed internals, on the performance of the gas-solid fluidized beds. Experimental investigation has been carried out in cylindrical column with and without twisted tapes. Twelve numbers of twisted tapes of three different widths with four values of the twist ratios for each width were studied at different...