2014
S Sina B Zeinali M Karimipoorfard F Lotfalizadeh M Sadeghi E Zamani R Faghihi

BACKGROUND Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. OBJECTIVE The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the a...

2015
H. WAGIRAN I. HOSSAIN S. A. B. IBRAHIM M. A. SAEED

Radiation effects of photon irradiation in Ytterbium-doped silica optical fibers are still much less explored despite their importance in space-based application as radiation dosimetry. This study investigates and compares the thermoluminescence glow curve, response, linearity and sensitivity of Ytterbium-doped SiO2 optical fibers with that of TLD-100. Samples are placed in solid phantom and ir...

Journal: :Medical physics 2012
P Alvarez J Aguirre S Smith D Followill

PURPOSE Analyze the characteristics of TLD LiF-100 powder between multiple LiF crystal batches. METHODS The RPC used TLD LiF-100 encapsulated powder to verify the output for photon and electron beams for 4 to 23 MV X-ray beams and 6 to 23 MeV electron beams, respectively, from the past 15 years. During that time period, the RPC commissioned more than 15 batches of TLD powder. Commissioning of...

2015
M. Sadeghi S. Sina R. Faghihi

LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...

2015
Raffaele Liuzzi Federica Savino Vittoria D’Avino Mariagabriella Pugliese Laura Cella Gabriele Multhoff

BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...

Journal: :journal of biomedical physics and engineering 0
m sadeghi radiation research center, shiraz university, shiraz, iran s sina nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran r faghihi nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran

lif, mg and ti cubical tld chips (known as tld-100) are widely used for dosimetry purposes. the repeatability of tl dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mgy) with 662kev photons of cs-137. a group of 40 cubical tld chips was randomly selected from a batch and the values of element correction coefficient (ecc) were obtained 4 times by irradiating them to doses...

Journal: :Analytical chemistry 2001
P D Wentzell S S Nair R D Guy

The application of trilinear decomposition (TLD) to the analysis of fluorescence excitation-emission matrices of mixtures of polycyclic aromatic hydrocarbons (PAHs) is described. The variables constituting the third-order tensor are excitation wavelength, emission wavelength, and concentration of a fluorescence quencher (nitromethane). The addition of a quencher to PAH mixtures selectively redu...

M Sadeghi, R Faghihi S Sina,

LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...

Journal: :Journal of Applied Clinical Medical Physics 2007

2014
S A Ibrahim S S Che Omar S Hashim G A Mahdiraji N M Isa

We have reported the thermoluminescence (TL) response of five different diameters ~120, 241, 362, 483, and 604 μm of 6 mol percent Ge-doped optical fibres. The perfomance of the Ge-doped optical fibre are compared with commercially available TLD-100 chips (LiF:Mg,Ti) in terms of their sensitivity and minimum detectable dose (MDD). The irradiation was performed using X-ray machine (Model ISO ‘Na...