نتایج جستجو برای: sysmex cell count

تعداد نتایج: 1777171  

Journal: :Rheumatology 2004
P Dieppe A Swan

OBJECTIVES To evaluate the performance of automated leucocyte (white blood cell; WBC) counting by comparison with manual counting. METHODS The number of WBC was determined in heparinized synovial fluid samples by the use of (i) a standard urine cytometer (Kova) and a microscope (reference method) and (ii) a haematology analyser (Sysmex XE-2100; WBC/BASO and DIFF channels). Imprecision within ...

Journal: :American journal of clinical pathology 2003
M Ali Ansari-Lari Thomas S Kickler Michael J Borowitz

We determined the usefulness of immature granulocyte measurement as a predictor of infection or positive blood culture and compared the results with total WBC count and absolute neutrophil count (ANC). Blood samples from 102 infected and 69 noninfected patients were analyzed using the Sysmex XE-2100 automated blood cell counter (Sysmex, Kobe, Japan). The percentage of immature granulocytes was ...

Journal: :American journal of clinical pathology 2002
Linda M Sandhaus Ebenezer S Osei Neeta N Agrawal Chrisine A Dillman Howard J Meyerson

We compared the accuracy and precision of the impedance platelet counts generated by the Beckman Coulter LH 750 and the Sysmex XE 2100 and the optical platelet counts produced by the Advia 120 and the Sysmex XE 2100 withflow cytometric reference platelet counts. Samples analyzed had platelet counts less than 150 x 10(3)/microL (150 x 10(9)/L) with a platelet flag or less than 75 x 10(3)/microL ...

Journal: :American journal of clinical pathology 2013
Margreet Schoorl Marianne Schoorl Jeanette Oomes Johannes van Pelt

OBJECTIVES In thrombocytopenia, high accuracy and precision of low platelet count is essential for appropriate decisions. The recently introduced Sysmex XN2000 analyzer (Sysmex, Kobe, Japan) offers 3 methods for platelet counting: impedance (PLT-I), optical (PLT-O), and a new fluorescence method (PLT-F). The precision of the PLT-F method in blood samples with platelet counts less than 50 × 10(3...

Journal: :Clinical chemistry and laboratory medicine 2002
Jan Van den Bossche Katrien Devreese Ronald Malfait Martine Van de Vyvere Annick Wauters Hugo Neeis Pieter De Schouwer

We processed 317 samples from healthy adult volunteers for a complete blood count, including leukocyte differentials and reticulocyte parameters, through five new-generation haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120. From these data non-parametric 2.5-97.5 percentile reference intervals were calculated for all parameters...

Journal: :Journal of clinical pathology 1991
W Goossens L Van Hove R L Verwilghen

To determine the accuracy of several methods for measuring the monocyte count, the results obtained by a number of different automated cell counters were analysed. Considerable discrepancies occurred for monocyte counts obtained in normal blood among the counters. The results of a visual monocyte count on a total of 800 leucocytes were used as the reference method. The technique of measuring th...

انصاری, شهلا, شهابی, اسماعیل , کاظمی, احمد,

    Background : Intravenous immunoglobulin (IVIG) is a plasma derived product. IVIG has been used in treatment of autoimmune, immunodeficiency and infectious diseases. In this study we assessed the effect of intravenous immunoglobulin administration on WBC, neutrophil, lymphocyte and platelet counts as well as the percent of CD4 and CD8 T-cell lymphocytes and number of lymphocytes in pediatric...

Journal: :American journal of clinical pathology 2014
Heidi Eilertsen Tor-Arne Hagve

OBJECTIVES The Sysmex XE-5000 instruments (Sysmex, Kobe, Japan) count immature granulocytes (IGs) and use the "Imm Gran?" flag to signal unreliable results. This study investigated the usefulness of the "Imm Gran?" flag and the analytical and diagnostic performance of the IG measurements in a side-by-side evaluation. METHODS In total, 408 samples were analyzed on three XE-5000 instruments. Th...

Journal: :Journal of clinical laboratory analysis 2003
Hisako Shibata Takahisa Yamane Ryousuke Yamamura Kensuke Ohta Takayuki Takubo Tomio Kamitani Masayuki Hino

The bone marrow aspiration test conventionally has been performed by visual methods, using a light microscope, because automatic blood cell analyzers cannot adequately capture erythroblasts and immature granulocytes (IGs) (Tatsumi et al.: Osaka City Med J 1988;34:135-146; Tatsumi et al.: Am J Clin Pathol 1986;86:50-54). With the development of the XE-2100 automatic blood cell analyzer (Sysmex C...

2016
Arshi Naz Samina Naz Mukry Mahwish Rauf Shaikh Ali Raza Bukhari Tahir Sultan Shamsi

BACKGROUND AND OBJECTIVE Immune thrombocytopenic purpura (ITP) is a clinical syndrome in which a decreased number of circulating platelets (thrombocytopenia) manifests as a bleeding tendency, easy bruising (purpura) or extravasation of blood from capillaries into skin and mucous membranes (petechiae). The diagnosis of ITP can be made clinically on the basis of symptoms, we need to see if ITP ca...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید