BACKGROUND The use of rest surface EMG of jaw elevator muscles is still debated. The low voltage recorded in anterior temporalis muscle by electromyography (EMG) in rest position could be affected by electronic noise or by activity coming from other muscles. Our goal was to evaluate the physiological behaviour of the anterior temporalis by surface EMG at rest mandible position during open or cl...
Textile electromyography (EMG) electrodes embedded in clothing allow muscle excitation to be recorded in previously inaccessible settings; however, their ability to accurately and reliably measure EMG during dynamic tasks remains largely unexplored. To quantify the validity and reliability of textile electrodes, 16 recreationally active males completed two identical testing sessions, within whi...
Motor unit action potentials (MUAPs) from motoneurons are transmitted to muscles through end-plates and then propagated to the tendons. These bioelectrical signals are detected via electromyography (EMG), which is performed using electrodes. The electrodes used in EMG are primarily surface electrodes and inserted (wire or needle) electrodes, of which surface and wire electrodes are mainly used ...
The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk was studied using finite element (FE) models of electromyogram (EMG) signal propagation. A FE model of the upper arm consisted of skin, fat, muscle and bone tissues in concentric layers. Single muscle fibre action potentials were simulated for muscle fibres at a variety of depths and combined to simulate surface EMG i...
The probability density function (PDF) of the surface electromyogram (EMG) signals has been modelled with Gaussian and Laplacian distribution functions. However, a general consensus upon the PDF of the EMG signals is yet to be reached, because not only are there several biological factors that can influence this distribution function, but also different analysis techniques can lead to contradic...
Surface electromyography is the technique for measuring levels of muscle activity. When a muscle contracts, electrical activity generated as action potentials propagate along the muscle fibers. There are two types of Surface EMG (SEMG)-Static scanning SEMG and Dynamic SEMG. In Dynamic SEMG, electrodes are attached to the skin and muscle activity is measured and graphed as the patient moves thro...
A linear relation between surface electromyogram (EMG) amplitude and muscle force is often assumed and used to estimate the contributions of selected muscles to various tasks. In the presence of muscle fatigue, however, changes in the properties of muscle fibre action potentials and motor unit twitch forces can alter the relation between surface EMG amplitude and force. A novel integrative mode...
BACKGROUND Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. METHODS A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surfa...