The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stress shielding of the bone were proven to adversely affect the lifelong stability of the implant, es...
BACKGROUND The main objective of every new development in total hip arthroplasty (THA) is the longest possible survival of the implant. Periprosthetic stress shielding is a scientifically proven phenomenon which leads to inadvertent bone loss. So far, many studies have analysed whether implanting different hip stem prostheses result in significant preservation of bone stock. The aim of this pre...
BACKGROUND Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is d...
OBJECTIVE This study aimed to evaluate the stress distribution and stress shielding effect of titanium miniplates used for the treatment of symphyseal fractures using finite element (FE) analysis. STUDY DESIGN Two 3-D FE models of symphyseal fractured mandibles reduced by technique 1, reduction with a single miniplate, and technique 2, reduction with 2 miniplates, respectively, were developed...
In total hip replacement (THR), bone resorption related to the foreign body reaction around the implant causes bonding failure at the bone-prosthesis interface and adversely affects the function and longevity of femoral implants. Stress shielding is thought to be one of the possible biomechanical factors that causes bone resorption, and is related to prosthesis design. We therefore investigated...
INTRODUCTION In the normal hip, stress is distributed over the entire crossection of the femur. Bending and axial compression are the major modes of loading. Following THA, the stress in the bone is significantly different mainly due to the manner in which the load is transferred to the femur (Huiskes, 1990, Huiskes, 1995). In this case, the load is primarily transferred through shear across th...
To ensure the biomechanical properties of Ti-24Nb-4Zr-8Sn, stress-shielding effects were compared between Ti-24Nb-4Zr-8Sn and Ti-6Al-4V fixation by using a porcine model. Twelve thoracolumbar spines (T12-L5) of 12-month-old male pigs were randomly divided into two groups: Ti-24Nb-4Zr-8Sn (EG, n = 6) and Ti-6Al-4V (RG, n = 6) fixation. Pedicle screw was fixed at the outer edge of L4-5 vertebral ...
The aim of this study was to test the hypothesis that a reinforced gamma nail for the fixation of subtrochanteric fractures would experience less stress during loading compared with a common gamma nail. The issue of whether the use of the stronger implant would result in more stress shielding in the surrounding bone was also addressed. A finite element analysis (FEA) of a synthetic bone was emp...