نتایج جستجو برای: static response

تعداد نتایج: 1077707  

The response speed of Web pages is one of the necessities of information technology. In recent years, renowned companies such as Google and computer scientists focused on speeding up the web. Achievements such as Google Pagespeed, Nginx and varnish are the result of these researches. In Customer to Customer(C2C) business systems, such as chat systems, and in Business to Customer(B2C) systems, s...

Journal: :journal of computational & applied research in mechanical engineering (jcarme) 2014
m. zamanian s. a. a. hosseini

this article studied static deflection, natural frequency and nonlinear vibration of a clamped-clamped microbeam under discontinues electrostatic actuation. the electrostatic actuation was induced by applying ac-dc voltage between the microbeam and electrode plate. in contrast to previous works, it was assumed that length of the electrode plate was smaller than that of the microbeam. in additio...

Journal: :journal of structural engineering and geo-techniques 2012
a azarbakht e rajabi

the aim of the present paper is to evaluate the influence of the soil- foundation- structure interaction (sfsi) effects on the component demand modifier factor of concrete gravity beams based on asce 41-06 standard. to this end, the beam on the nonlinear winkler foundation approach is employed which is a simple and efficient method. at first, four sets of 3-, 6-, 10- and 15-storey concrete mome...

H. Akbarzade Bengar O. Yazdanpanah S.M. Seyedpoor,

In this paper, the capabilities of displacement curvature derived from static response data for finding the location and severity of damage in Euler-Bernoulli beams are assessed. Static response of a beam is obtained using the finite element modeling. In order to reduce the number of measured nodal displacements, the beam deflection is fitted through a polynomial function using a limited number...

M. Zamanian S. A. A. Hosseini

This article studied static deflection, natural frequency and nonlinear vibration of a clamped-clamped microbeam under discontinues electrostatic actuation. The electrostatic actuation was induced by applying AC-DC voltage between the microbeam and electrode plate. In contrast to previous works, it was assumed that length of the electrode plate was smaller than that of the microbeam. In additio...

Journal: :Journal of Intelligent Material Systems and Structures 2007

Journal: :international journal of civil engineering 0
m. mahmoudi shahid rajaee teacher training university t. teimoori shahid rajaee teacher training university h. kozani shahid rajaee teacher training university

the current building codes provide limited prescriptive guidance on design for protection of buildings due to progressive collapse. progressive collapse is a situation in which a localized failure in a structure, caused by an abnormal load, such as explosions or other happenings. three procedures, often employed for determination of the structural response during progressive collapse i.e. linea...

The present research is concerned with the determination of ductility, over-strength and response modification factors of coupled steel shear wall frames. Three structural models with various numbers of stories, bay width and coupling beam height were analyzed using static pushover and incremental nonlinear dynamic analyses. The ductility, over-strength and response modification factors for the...

A Azarbakht, E Rajabi

The aim of the present paper is to evaluate the influence of the Soil- Foundation- Structure Interaction (SFSI) effects on the component demand modifier factor of concrete gravity beams based on ASCE 41-06 standard. To this end, the beam on the nonlinear Winkler foundation approach is employed which is a simple and efficient method. At first, four sets of 3-, 6-, 10- and 15-storey concrete mome...

F. Rahimzadeh Rofooei and H. Saadatnia,

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید