نتایج جستجو برای: speckle tracking

تعداد نتایج: 120123  

2013
Toshinari Onishi Samir K Saha Daniel R Ludwig Tetsuari Onishi Josef J Marek João L Cavalcante Erik B Schelbert David Schwartzman John Gorcsan

BACKGROUND Analysis of left ventricular (LV) mechanical dyssynchrony may provide incremental prognostic information regarding cardiac resynchronization therapy (CRT) response in addition to QRS width alone. Our objective was to quantify LV dyssynchrony using feature tracking post processing of routine cardiovascular magnetic resonance (CMR) cine acquisitions (FT-CMR) in comparison to speckle tr...

Journal: :Medical image analysis 2015
Ariel Hernán Curiale Gonzalo Vegas-Sánchez-Ferrero Johan G. Bosch Santiago Aja-Fernández

The strain and strain-rate measures are commonly used for the analysis and assessment of regional myocardial function. In echocardiography (EC), the strain analysis became possible using Tissue Doppler Imaging (TDI). Unfortunately, this modality shows an important limitation: the angle between the myocardial movement and the ultrasound beam should be small to provide reliable measures. This con...

2014
Tudor Trache Stephan Stöbe Adrienn Tarr Dietrich Pfeiffer Andreas Hagendorff

Comparison of 3D and 2D speckle tracking performed on standard 2D and triplane 2D datasets of normal and pathological left ventricular (LV) wall-motion patterns with a focus on the effect that 3D volume rate (3DVR), image quality and tracking artifacts have on the agreement between 2D and 3D speckle tracking. 37 patients with normal LV function and 18 patients with ischaemic wall-motion abnorma...

2011
Kazuhiro Tatsumi Hidekazu Tanaka Takayuki Tsuji Akihiro Kaneko Keiko Ryo Kohei Yamawaki Alaa MS Omar Yuko Fukuda Kazuko Norisada Kensuke Matsumoto Tetsuari Onishi Akihiro Yoshida Hiroya Kawai Ken-ichi Hirata

BACKGROUND We have previously reported strain dyssynchrony index assessed by two-dimensional speckle tracking strain, and a marker of both dyssynchrony and residual myocardial contractility, can predict response to cardiac resynchronization therapy (CRT). A newly developed three-dimensional (3-D) speckle tracking system can quantify endocardial area change ratio (area strain), which coupled wit...

Journal: :Medical image analysis 2016
Ariel Hernán Curiale Gonzalo Vegas-Sánchez-Ferrero Santiago Aja-Fernández

Speckle Tracking is one of the most prominent techniques used to estimate the regional movement of the heart based on ultrasound acquisitions. Many different approaches have been proposed, proving their suitability to obtain quantitative and qualitative information regarding myocardial deformation, motion and function assessment. New proposals to improve the basic algorithm usually focus on one...

Journal: :Journal of biomedical optics 2015
Vladimir Y Zaitsev Alexandr L Matveyev Lev A Matveev Grigory V Gelikonov Valentin M Gelikonov Alex Vitkin

Feasibility of speckle tracking in optical coherence tomography (OCT) based on digital image correlation (DIC) is discussed in the context of elastography problems. Specifics of applying DIC methods to OCT, compared to processing of photographic images in mechanical engineering applications, are emphasized and main complications are pointed out. Analytical arguments are augmented by accurate nu...

Journal: :Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography 2005
Charlotte Bjork Ingul Hans Torp Svein Arne Aase Sigrid Berg Asbjorn Stoylen Stig A Slordahl

BACKGROUND This study evaluated 3 new automated methods, based on a combination of speckle tracking and tissue Doppler, for the analysis of strain rate (SR) and strain. Feasibility and values for peak systolic strain rate (SR s ) and end-systolic strain (S es ) were assessed. METHODS Thirty patients with myocardial infarction and 30 normal subjects were examined. Customized software with auto...

Journal: :archives of cardiovascular imaging 0
maryam esmaeilzadeh echocardiography research center, rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, ir iran; tufts medical center, cardiovascular imaging, ultrasound research lab, boston, usa farveh vakilian atherosclerosis prevention research center, mashhad university of medical sciences, mashhad, ir iran; atherosclerosis prevention research center, mashhad university of medical sciences, mashhad, ir iran. tel: +98-9153162670, fax: +98-5118544504 majid maleki echocardiography research center, rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, ir iran ahmad amin rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, ir iran sepideh taghavi rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, ir iran hooman bakhshandeh rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, ir iran

background two-dimensional (2d) strain is a new reproducible technique for assessing regional myocardial function; however, its application for evaluation of left atrium (la) function is less studied. objectives we sought to assess la function in heart failure patients using velocity vector imaging (vvi). patients and methods thirty five patients (mean age: 43.34 ± 18.1 years, 59.3% male) with ...

2015
David Prater

To measure the strain, the tissue motion is tracked over a cardiac cycle using a speckle tracking algorithm. Similar to MRI tagging, speckle tracking follows features within the image as they move. Each sub-region of the ROI is divided into blocks, which allows the speckle structure in each block to be tracked. The measured deformation for each sub-region is a weighted combination of the displa...

Journal: :Acta radiologica 2016
Åsa Fröberg Mattias Mårtensson Matilda Larsson Birgitta Janerot-Sjöberg Jan D'Hooge Anton Arndt

BACKGROUND Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. PURPOSE To investigate the feasibility of u...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید