نتایج جستجو برای: saturation having reached near 85 by pulse oximetry

تعداد نتایج: 7354754  

Journal: :iranian journal of medical sciences 0
seiyed mohammad ali ghayumi department of internal medicine, nemazee hospital, shiraz university of medical sciences, shiraz, iran mohammad javad fallahi department of internal medicine, nemazee hospital, shiraz university of medical sciences, shiraz, iran; ali reza moarref cardiovascular research center, faghihi hospital, shiraz university of medical sciences, shiraz, iran

background: it was hypothesized that the use of pentoxifylline would increase arterial o2 saturation and increase exercise tolerance in patients with chronic obstructive pulmonary disease (copd). methods: we tested this hypothesis in 23 patients with copd and pulmonary hypertension. patients were randomized to receive pentoxifylline or placebo, each for a 12-week period, in a prospective, doubl...

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

Journal: :hepatitis monthly 0
seiyed mohammad ali ghayumi department of internal medicine, shiraz university of medical sciences, shiraz, ir iran abolfazl khalafi-nezhad department of internal medicine, shiraz university of medical sciences, shiraz, ir iran; corresponding author: abolfazl khalafi-nezhad, department of internal medicine, shiraz university of medical sciences, shiraz, ir iran. tel: +98-7116474316, fax: +98-7116474316, e-mail: zahra jowkar department of operative dentistry, school of dentistry, shiraz university of medical sciences, shiraz, ir iran

results roc-derived spo2 threshold of ≤ 94% can predict hypoxemia (pao2 < 60 mmhg) with a sensitivity of 100% and a specificity of 95%. furthermore, there are associations between the roc-derived spo2 threshold of ≤ 97% and detection of hypoxemia (pao2 < 70 mmhg) with a sensitivity of 100% and a specificity of 46%. the accuracy of pulse oximetry was not affected by the severity of liver disease...

2011
Ross C. Puffer David F. Kallmes

We present a case of a 63-year-old male undergoing attempted basilar artery embolization using a right transradial artery approach in which continuous pulse oximetry of the ipsilateral thumb uncovered unanticipated hand ischemia during the procedure. A preprocedural evaluation using pulse oximetry of the right thumb demonstrated normal waveform and maintenance of normal oxygen saturation during...

Journal: :Archives of disease in childhood 1989
P Pianosi T D Charge D W Esseltine A L Coates

Patients with sickle cell disease usually have mild hypoxaemia and their oxyhaemoglobin dissociation curve is shifted to the right. It follows that oxygen saturation in sickle cell disease should be lower than normal. Most subjects in this clinic had normal oxygen saturation by pulse oximetry, however. To improve the understanding of this paradox, arterialised capillary oxygen tension (PO2) and...

Journal: :Pediatrics 1997
W R Mower C Sachs E L Nicklin L J Baraff

PURPOSE To determine the utility of pulse oximetry as a routine fifth vital sign in acute pediatric assessment. DESIGN Prospective study using pulse oximetry to measure oxygen saturation in children presenting to emergency department triage. Saturation values were disclosed to clinicians only after they had completed medical evaluations and were ready to discharge or admit each child. We meas...

Journal: :AANA journal 1988
G W Henderson

Continuous noninvasive monitoring of oxygenation in premature neonates with respiratory distress is essential to avoid the potential complications of hypoxemia and hyperoxia. The accuracy and reliability of pulse oximetry (using an Ohmeda Biox) was evaluated in 15 premature neonates. Pulse oximetry oxygen saturation readings closely approximated arterial oxygen saturation values analyzed by an ...

Journal: :Clinical chemistry 2005
Shannon Haymond Rohit Cariappa Charles S Eby Mitchell G Scott

BACKGROUND This case conference reviews laboratory methods for assessing oxygenation status: arterial blood gases, pulse oximetry, and CO-oximetry. Caveats of these measurements are discussed in the context of two methemoglobinemia cases. CASES Case 1 is a woman who presented with increased shortness of breath, productive cough, chest pain, nausea, fever, and cyanosis. CO-oximetry indicated a...

2006
Ebrahim Razi Hossein Akbari

INTRODUCTION Pulse oximetry is a useful tool for clinical and investigational purposes for indirect measurements of oxygen saturation [1-3]. Measurement of oxygen saturation with pulse oximetry (SpO2) can be used for evaluation and control of hypoxemia in chronic obstructive pulmonary disease (COPD). As pulse oximetry is a non–invasive device, it can be used instead of arterial blood gases (ABG...

2009
Jung-Hwan Choi Won Soon Park Chong Ku Yun

=Abstract=Pulse oximetry has recently been introduced as a method for continuous and non-invasive transcutaneous monitoring of arterial oxygen saturation in neonates. The purpose of our study was to determine the reliability, accuracy, and practicability of pulse oximetry for monitoring arterial oxygenation in sick newborn infants. Pulse oximetry oxygen saturation values (SpO2) were compared wi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید