نتایج جستجو برای: residual unbalance
تعداد نتایج: 92753 فیلتر نتایج به سال:
This paper explains a mechanism of commonmode generation on a printed circuit board with a narrow ground pattern. A transmission line has its value of degree of unbalance. At a connection point of two transmission lines having different degrees of unbalance, common mode voltage is generated proportional to the difference, and it drives common mode current. The authors propose a method to evalua...
In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control of distributed generators (DGs). The DGs control structure mainly consists of active and reactive power contro...
Objectives: This study proposes a droop controlled voltage unbalance reimbursement technique in an islanded microgrid. Methods/Analysis: The control system is executed in áâ static reference frame work. Here the distributed generators (DGs) inverters are managed appropriately to compensate imbalance in allocating active as well as reactive powers. The control system includes active as well as r...
در این پایان نامه ابتدا روش های لانکسوز و روش های تکراری را مطرح می کنیم و سپس روش های گرادیان مزدوج و مانده مزدوج را با جهتهای جستجو مطرح کرده و تعمیم می دهیم روش های bi-conjugat gradiant و bi-conjugat residual را مطرح کرده و نتایج عددی حاصل را بیان کرده و نتیجه میگیریم که bi-conjugat residual بهتر از bi-conjugat gradiant می باشند.
The unbalanced non-sinusoidal operation represents a common steady state of the modern distribution power grids. The unbalance is produced by supplying of unbalanced loads or by different unbalanced faults. According to the existing norms, this operating state is evaluated using the well-known negative and zero unbalance factors that practically keep out the harmonic pollution that coexists wit...
Abstract: This paper presents a sequence networks based methodology for investigating voltage unbalance in distribution networks with renewable generation. The sequence networks are derived from the original asymmetrical three-phase network, and then interconnected to study sequence voltages and unbalance propagation through the network. The approach enables to analyse the influence of line imp...
Disk unbalance in rotating shaft of machines is a common problem. Direct measurement of unbalance forces due to disk unbalance is not possible, therefore, usually the unbalance forces are predicted via response measurements. In the present work, a model-based approach with joint input-state (JIS) estimation technique to detect the amount of unbalance present in a disc is proposed. The JIS techn...
For islanded microgrids, droop-based control concepts have been developed both in single and three-phase variants. The three-phase controllers often assume a balanced network; hence, unbalance sharing and/or mitigation remains a challenging issue. Therefore, in this paper, unbalance is considered in a three-phase islanded microgrid in which the distributed generation (DG) units are operated by ...
This paper presents a numerical study of the system unbalance and the fault impedance effect on faulted power system analysis. Two short circuit techniques, the symmetrical components and phase components algorithms are implemented and analyzed based on numerical simulations of the IEEE 13 bus test feeder. Test cases include voltage unbalance effect and fault impedance effect on during-fault vo...
The effects of dynamic loading on crack breathing mechanisms are not yet thoroughly examined in literature. This paper introduces a parameter relating crack direction to bending load direction in order to model breathing behaviour of fatigue cracks subject to mass unbalance. Crack states (open, partial and closed) for shafts subject to weight-to-unbalance force ratios of 0.5, 1 and 2 and unbala...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید