نتایج جستجو برای: radiochromic film dosimetry

تعداد نتایج: 98518  

Hasan Nedaie Majid Shariari Zahra Anjomani,

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

2012
Mahdi Ghorbani Mohammad Taghi Bahreyni Toossi Ali Asghar Mowlavi Shahram Bayani Roodi Ali Soleimani Meigooni

UNLABELLED BACKGROUND.: The aim of this study is to evaluate the performance of a color scanner as a radiochromic film reader in two dimensional dosimetry around a high dose rate brachytherapy source. MATERIALS AND METHODS A Microtek ScanMaker 1000XL film scanner was utilized for the measurement of dose distribution around a high dose rate GZP6 (60)Co brachytherapy source with GafChromic® EBT...

2014
Antony L Palmer David Bradley Andrew Nisbet

The measurement of dose distributions in clinical brachytherapy, for the purpose of quality control, commissioning or dosimetric audit, is challenging and requires development. Radiochromic film dosimetry with a commercial flatbed scanner may be suitable, but careful methodologies are required to control various sources of uncertainty. Triple-channel dosimetry has recently been utilized in exte...

Journal: :journal of biomedical physics and engineering 0
m t bahreyni toossi medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran f khorshidi medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) m ghorbani medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) n mohamadian medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences) d davenport comprehensive cancer centers of nevada, las vegas, nevada, usaسازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (mashhad university of medical sciences)

background: ebt and ebt3 radiochromic films have been used in radiotherapy dosimetry for years. objective: the aim of the current study is to compare ebt and ebt3 radiochromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. methods: calibrations of ebt and ebt3 films were performed with identical setups using a 6 mv photon beam of a siemens primus linac. skin dose was...

2016
Elsa Y. León Marroquin José A. Herrera González Miguel A. Camacho López José E. Villarreal Barajas Olivia A. García‐Garduño

Radiochromic film has become an important tool to verify dose distributions for intensity-modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the for...

Journal: :Physics in medicine and biology 2001
M J Butson T Cheung P K Yu

Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of film orientation during irradiation in water are also tested. Results show that only a small penetration rate ...

Journal: :iranian journal of science and technology (sciences) 2008
a. akhavan

in order to improve the performance of a newly developed radiochromic film, gic-79, somedosimetric characteristics of this film have been studied based on relevant standard practice. the presentstudy describes some parameters that may affect the dosimeter response before, during, and after irradiation. the effect of absorbed dose rate on dosimeter response was determined by irradiating dosimete...

2012
Frédéric Girard Hugo Bouchard Frédéric Lacroix

The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparin...

Journal: :Journal of Applied Clinical Medical Physics 2012

C Knaup, F Akbari F Khorshidi, M Ghorbani, M T Bahreyni Toosi N Mohammadian

Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3...