نتایج جستجو برای: pvc based membrane

تعداد نتایج: 3283838  

Journal: :journal of physical & theoretical chemistry 2011
m.h. fekri m. darvishpour e. baghdar

a poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a cr(iii) selective electrode. the electrode exhibits a good potentiometric response for cr(iii)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 m with a slope 19.5+0.5 mv/decade and low detectionlimit of 8.9 x 10-7 m. it has a fast response time < 15 s. the best perfo...

Journal: :journal of physical & theoretical chemistry 2015
h. aghaie m. h. felcri m. arvand k. zare m. aghaie

a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...

Journal: :iranian journal of pharmaceutical research 0
farhad ahmadi 1- drug delivery research center, faculty of pharmacy, kermanshah university of medical sciences, kermanshah, islamic republic of iran. 2-department of medicinal chemistry, faculty of pharmacy, kermanshah university of medical sciences, kermanshah, islamic republic of iran. nasim assadi department of medicinal chemistry, faculty of pharmacy, kermanshah university of medical sciences, kermanshah, islamic republic of iran.

a novel potentiometric ion-selective pvc membrane sensor for analysis of atorvastatin (at) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (at-(tpb)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (top) as plasticizer solvent was prepared. the electrode shows a good nernestian response over the concentration range of 0.09–5586 µg ...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaie karim zare ali reza abedin mehran aghaie

a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1390

abstract ion selective electrodes (ises) are electrochemical sensors that respond selectivity to the activity of ionic species. an ion-selective electrode is an electrochemical device that uses a thin selective membrane or film as the recognition element, and is an electrochemical half-cell equivalent to other half-cells of the zeroth (inert metal in a redox electrolyte). in common methods o...

M. Darvishpour M. H. Fekri

A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...

2006
Dana Vlascici Eugenia Fagadar-Cosma Otilia Bizerea-Spiridon

In the present paper, the potentiometric response characteristics of a metalloporphyrin-based electrode in o-nitrophenyloctylether (o-NPOE) plasticized polyvinyl chloride (PVC) membrane are presented for a set of monovalent anions. As membrane ionophore, 5,10,15,20-tetrakis-(4-methoxyphenyl)-porphyrin-Co(II) (CoTMeOPP) was used. To establish the optimum composition of the membrane, different mo...

H. Aghaie M. Giahi M. Zawari

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n&apos;1,n&apos;2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید