نتایج جستجو برای: potentiometric detection

تعداد نتایج: 568557  

2013
R. Pérez-Olmos

A rapid and simple sequential potentiometric method is described for the determination of nitrate and chloride ions in vegetables, by using home-made ion selective electrodes. The extraction of both ions from the vegetable samples was effected by magnetic stirring of the samples during 30 min in water at room temperature. Direct Potentiometry was used as analytical technique for measurement. Th...

Journal: :Talanta 2010
Sara M Oliveira Teresa I M S Lopes Ildikó V Tóth António O S S Rangel

A multicommuted flow system with the propulsion device placed before detection is proposed for the determination of tartaric acid and free potassium in table and Port wines. A dialysis unit was introduced to increase sample dilution and minimize matrix interferences. The determination of tartaric acid was based on the spectrophotometric monitorization of the complex formed by the dialyzed analy...

2002
Joachim P. Kloock Yulia G. Mourzina Jürgen Schubert Michael J. Schöning

A first step towards a microfabricated potentiometric thin-film sensor array for the simultaneous detection of Pb, Cd and Cu has been realized. The sensitive layers used are on the basis of chalcogenide glass materials. These thin-film chalcogenide glass materials that consist of mixtures of Pb-Ag-As-I-S, Cd-Ag-As-I-S or Cu-Ag-As-Se have been prepared by pulsed laser deposition technique. The d...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2015
abolfazl darroudi hossein eshghi shima rezaeian mahmoud chamsaz mehdi bakavoli

carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (vo2+) in aqueous medium. the new ligand was synthesized in three steps with high yield. the optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), and sodium tetra...

2015
Rongning Liang Lusi Chen Wei Qin

Ion-selective electrode (ISE) based potentiometric gas sensors have shown to be promising analytical tools for detection of chemical vapors. However, such sensors are only capable of detecting those vapors which can be converted into ionic species in solution. This paper describes for the first time a polymer membrane ISE based potentiometric sensing system for sensitive and selective determina...

2014
Ahmed Abu Ismaiel Mohamed Kheireddine Aroua Rozita Yusoff

In this study, a potentiometric sensor composed of palm shell activated carbon modified with trioctylmethylammonium thiosalicylate (TOMATS) was used for the potentiometric determination of mercury ions in water samples. The proposed potentiometric sensor has good operating characteristics towards Hg (II), including a relatively high selectivity; a Nernstian response to Hg (II) ions in a concent...

2012
Reza Ansari

Potentiometric sensor based on commercial pencil graphite electrodes coated with polyaniline (PAni) composite with Eosin Y (EY) termed as PGE/PAni-EY have been developed for potentiometric determination of silver ion. The electrode exhibited linear response with Nernstian slope of 57.6±0.8 mV per decade within the range of 1.0×10 to 1.0×10 M with limit of detection 6.5×10 M silver ion. Fast and...

Journal: :Chemical research in toxicology 1998
Artz Thatcher

Unraveling the biology, pharmacology, and toxicology of NO depends on accurate NO assays, two of the more common being the oxyHb (oxyhemoglobin) assay and potentiometric detection using a Clark-type NO-selective electrode. Comparison of the specificity and sensitivity of the oxyHb and potentiometric methods was carried out using a broad series of nitrovasodilators, including organic nitrates, n...

2008
Gabriela Broncová Tatiana V. Shishkanova Martin Krondak Radko Volf Vladimír Král

This report presents an optimization of potentiometric measurements withcitrate-selective electropolymerized poly(neutral red) electrodes. The optimal backgroundelectrolyte for these measurements is a TRIS buffer with nitrate at pH 8.5. The electrodesdescribed here exhibit stable and reproducible near-Nernstian response to citrates with alow detection limit of 6 × 10-6 M. Electrodes polymerized...