نتایج جستجو برای: plate loading test
تعداد نتایج: 945515 فیلتر نتایج به سال:
We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II),...
BACKGROUND Fixation of radial neck fractures can be achieved with a plate and screw construct or with two screws. This study evaluated the biomechanical properties of three different fixation methods following radial neck fractures. METHODS Twenty-four fourth-generation composite radii were sawed to simulate an unstable radial neck fracture. They were then instrumented with a plate and screw ...
experimental study of steel plate shear walls with composite steel infill platesunder cyclic loading
in this paper, nonlinear behavior of composite steel plate shear wall systems, in which steel infill plate is strengthened by fiber reinforced polymer (frp) layers, are experimentally investigated. tests are designed to evaluate the effect of glass-frp layers, layers number of gfrp and orientation of gfrp layers on the stiffness, shear strength, cumulative dissipated energy and other seismic pa...
Background Fixation of proximal chevron metatarsal osteotomy has been accomplished using K-wires traditionally and with a locking plate recently. However, both methods have many disadvantages. Hence, we developed an intramedullary fixation technique using headless cannulated screws and conducted a biomechanical study to evaluate the superiority of the technique to K-wire and locking plate fixat...
in this paper, a sensitivity analysis of artificial neural networks (nns) is presented and employed for estimating the patch load resistance of plate girders subjected to patch loading. to evaluate the accuracy of the proposed nn model, the results are compared with the previously proposed empirical models, so that we can estimate the resistance of plate girders subjected to patch loading. the ...
The goal of this study was to determine whether there is any biomechanical difference in terms of construct strength with axial loading between volar fixed-angle locking plates with threaded locking vs smooth locking pegs. The control group comprised 7 cadaveric specimens with threaded locking pegs, and the test group comprised 7 cadaveric specimens from the same donor with smooth locking pegs....
PURPOSE The purpose of this study was to determine the effect of number of chewing strokes on change in blood flow in denture-supporting maxillary mucosa. METHODS Subjects consisted of 11 healthy dentate men. Mastication was simulated by intermittent loading (10 N, 1/0.75 Hz) on a lateral area of the hard palate using a 2-cm(2) test plate. Loading duration was set at 1, 4, 8 or 12 min (80, 32...
BACKGROUND Implants for fracture and/or osteotomy fixation are often tested according to basic mechanical test models such as open gap tests or 4-point-bending tests. These may be suitable to test and compare different implants for safety and clinical approval, but are not always representative of the post-operative situation, which is decisive when it comes to bone healing. In the current stud...
BACKGROUND The purpose of the present study was to compare the mechanical static and fatigue strength of the size 2 osteotomy plate "Activmotion" with the following five other common implants for the treatment of medial knee joint osteoarthritis: the TomoFix small stature, the TomoFix standard, the Contour Lock, the iBalance and the second generation PEEKPower. METHODS Six fourth-generation t...
OBJECTIVE Malposition of the femoral Less Invasive Stabilization System (LISS) plate may alter its biomechanical behavior. This study compares the mechanical stability of "correctly" affixed LISS plates matching the slope of the lateral femoral condyle to "incorrectly" placed LISS plates fixed in external rotation relative to the distal femur. METHODS A fracture gap model was created to simul...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید