نتایج جستجو برای: pixelated collimator

تعداد نتایج: 3420  

Journal: :Bible and the Contemporary World 2020

Journal: :International Journal of Computer Vision 2019

Journal: :Medical physics 2014
M Khan J Rehman J Chow

PURPOSE The purpose of this study is to investigate the dose-volume variations of planning target volume (PTV) and organs-at-risk (OARs) in prostate volumetric modulated arc therapy (VMAT) when using different collimator angles. It is because collimator angle awareness is essential for planner to produce an optimal prostate VMAT plan in a rational time. METHODS Single-arc VMAT plans at differ...

Journal: :Nuclear Engineering and Technology 2021

In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and air filter, was developed. A collimator applied to the system showed enhancement in resolution degradation efficiency. The efficiency were compared analyzed evaluate performance collimator. Thus, found be more important than as determining factor performance, from viewp...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1990
R E Malmin P C Stanley W R Guth

Angulation errors in collimator septa degrade tomographic resolution in SPECT due to mispositioning of events in the projection data. These errors should be small compared to other contributions to SPECT system resolution, such as intrinsic camera and collimator resolution, gantry alignment, and algorithmic smoothing. We describe a radioisotope technique to measure septal angulation errors over...

Journal: :Medical physics 2002
Gengsheng L Zeng Daniel Gagnon Christopher G Matthews Jeffery A Kolthammer Jason D Radachy William G Hawkins

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted plan...

Journal: :Journal of nuclear medicine technology 2011
Erin R Snay S Ted Treves Frederic H Fahey

UNLABELLED Our objective was to optimize the quality of (123)I-metaiodobenzylguanidine (MIBG) scans by using a medium-energy collimator to reduce high-energy-photon septal penetration. METHODS In addition to the 159-keV γ-ray, (123)I has a small abundance of energies above 400 keV that can compromise the image quality of MIBG studies because of septal penetration. Using a low-energy ultrahigh...

Journal: :Fortschritte der Physik 2019

2012
Sudahar Harikrishnaperumal Gopalakrishna Kurup Murali Venkatraman Velmurugan Jagadeesan

Prolonged treatment execution time is a concern in CyberKnife robotic radiosurgery. Beam reduction and node reduction technique, and monitor unit optimization methods are adopted to reduce the treatment time. Usage of single collimator in the CyberKnife treatment plan can potentially reduce collimator exchange time. An optimal single collimator, which yields an acceptable dose distribution alon...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید