نتایج جستجو برای: organ peripheral dose

تعداد نتایج: 574429  

M. Shahriari, M.R. Ay, P. Ghafarian, S. Sarkar,

Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...

بنایی, امین, بیجاری, سالار, خرمیان, داریوش, سیستانی, سروش,

Background: There are several techniques for reducing the delivered dose from CT (Computed tomography) scanning such as the automatic exposure control (AEC). This technique modulates the tube current regarding the patient size and weight. The aim of this study was to estimate the effect of the AEC on the radiosensitive organs effective doses in women undergoing chest CT scanning. Methods: This...

الهی, مهدی, بیجاری, سالار, خرمیان, داریوش, سیستانی, سروش,

Introduction: There are several techniques for reducing the delivered dose from CT scans such as the automatic exposure control (AEC). This technique regulates the tube current regarding the patient size and weight. The aim of this study was estimation the effective and equivalent dose for radiosensitive organs in women undergoing chest CT scans with or without AEC system using the patient&rsqu...

Journal: :iranian journal of radiation research 0
m.r. ay department of physics, amir kabir university & tpp co., tehran, iran m. shahriari s. sarkar p. ghafarian

background: ct is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in ct exams is very important. while methods to calculate the effective dose have been established (icrp 26 and icrp 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the ct procedure. however, dete...

Abdolazim Sedighi Fahimeh Rezaei, Mohammad Hadi Gholami Mohammad Mohammadi, Ramin Jaberi

Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments.   Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...

E. Esmati, H. Nosrati, H.A. Nedaie, M. Jamali, N. Banaee,

Background: In radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. One of these critical organs in pelvic irradiation is testis. The amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. The threshol...

Journal: :iranian journal of radiation research 0
h. acar department of radiation oncology, selcuklu faculty of medicine, selcuk university, turkey g. yavas department of radiation oncology, selcuklu faculty of medicine, selcuk university, turkey c. yavas department of radiation oncology, konya training and research hospital, turkey

background: in radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. in this study, the two available calculation algorithms of the varian eclipse 8.6 treatment planning system(tps), the anisotropic analytic algorithm (aaa) and pencil-beam convolution (pbc) was used to compare measured and calculated peripheral dose distributi...

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

Journal: :The Boston Medical and Surgical Journal 1894

2012
Ming X. Jia Xu Zhang Na Li En Y. Wang Da W. Liu Wei S. Cai

The growing use of cone-beam computed tomography (CBCT) for IGRT has increased concerns over the additional radiation dose to patients. The in-field dose of IGRT and the peripheral dose (PD) from kilovoltage CBCT (KV-CBCT) imaging have been well quantified. The purpose of this work is to evaluate the peripheral dose from megavoltage CBCT (MV-CBCT) imaging for nasopharyngeal carcinoma IGRT, to d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید