نتایج جستجو برای: observer reproducibility

تعداد نتایج: 52932  

2017
Yang Sun Chuan Ma XiaoLong Liang Run Wang Ying Fu ShuMin Wang LiGang Cui ChunLei Zhang

Shear Wave Elastography (SWE) is an objective and non-invasive method widely used to quantify the tissue solidity. However, there are concerns about the accuracy of the skin SWE results due to the low signal-to-noise ratio (SNR) caused by subcutaneous fat, muscle and bone. This article analyzed the reproducibility of the result for skin SWE and therefore evaluated the availability of SME for sk...

Journal: :European heart journal cardiovascular Imaging 2016
Edouard Gerbaud Giora Weisz Atsushi Tanaka Manabu Kashiwagi Takehisa Shimizu Lin Wang Christiano Souza Brett E Bouma Melissa J Suter Milen Shishkov Giovanni J Ughi Elkan F Halpern Mireille Rosenberg Sergio Waxman Jeffrey W Moses Gary S Mintz Akiko Maehara Guillermo J Tearney

AIMS The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. METHODS AND RE...

2013
Christopher M Haggerty Sage P Kramer Cassi M Binkley David K Powell Andrea C Mattingly Richard Charnigo Frederick H Epstein Brandon K Fornwalt

BACKGROUND Advanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both ...

2005
Celso Tello Jeffrey Liebmann Seth D. Potash Henry Cohen Robert Ritch

Methods. Four anterior segment images of four normal patients were obtained by a single examiner. The measurements of three independent observers were compared to assess interobserver reproducibility in quantifying the images. Thirteen different anterior segment parameters were measured by each observer on each image. Intraobserver and interobserver reproducibility of measurement were assessed ...

Journal: :The European respiratory journal 1994
A Díez Herranz

I have read with interest the paper by SENÉTERRE et al. [1]. However, perhaps the method used to assess the reproducibility of the measurements is not the best one. The authors use Spearman's rank test, and they find an "excellent and highly significant" reproducibility, since r-value is 0.99 in all cases. Considering that correlation is different from agreement, BLAND and ALTMAN [2] have propo...

طیبی میبدی, ناصر, عموئیان, سکینه, فرهادی, فرزانه,

  Background and Aim: Chronic gastritis is one of the most common gastrointestinal disorders and detection of its etiology especially Helicobacter pylori and risk factors of malignancy (atrophy and intestinal metaplasia) is, to a great extent, based on histological assessment. Therefore, a system which could sustain good reproducibility in reporting observations is very important. Today, the mo...

Journal: :The Journal of bone and joint surgery. British volume 2006
I A Malek B Machani A M Mevcha N H Hyder

Our aim was to assess the reproducibility and the reliability of the Weber classification system for fractures of the ankle based on anteroposterior and lateral radiographs. Five observers with varying clinical experience reviewed 50 sets of blinded radiographs. The same observers reviewed the same radiographs again after an interval of four weeks. Inter- and intra-observer agreement was assess...

Journal: :European heart journal cardiovascular Imaging 2016
Chikara Noda Bharath Ambale Venkatesh Yoshiaki Ohyama Chia-Ying Liu Elzbieta Chamera Alban Redheuil Gisela Teixido-Tura Atul R Chugh Colin O Wu Gregory W Hundley David A Bluemke Joao A C Lima

AIMS To assess the test-retest, intra- and inter-reader reliability of thoracic aorta measurements by magnetic resonance imaging (MRI). METHODS AND RESULTS Twenty-five participants underwent aortic MRI twice over 13 ± 7 days. All aortic variables from baseline and repeat MR were analysed using a semi-automated method by the ARTFUN software. To assess the inter-study reproducibility of aortic ...

2017
Tomas Lapinskas Jana Grune Seyedeh Mahsa Zamani Sarah Jeuthe Daniel Messroghli Rolf Gebker Heike Meyborg Ulrich Kintscher Remigijus Zaliunas Burkert Pieske Philipp Stawowy Sebastian Kelle

BACKGROUND Cardiovascular magnetic resonance feature tracking (CMR-FT) is a novel tissue tracking technique developed for noninvasive assessment of myocardial motion and deformation. This preliminary study aimed to evaluate the observer's reproducibility of CMR-FT in a small animal (mouse) model and define sample size calculation for future trials. METHODS Six C57BL/6 J mice were selected fro...

Journal: :Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology 2003
I Y Järvelä P Sladkevicius A H Tekay S Campbell G Nargund

OBJECTIVE To assess intraobserver and interobserver variability in ovarian volume and gray-scale and color flow index measurements using transvaginal, three-dimensional, power Doppler ultrasonography. METHODS Eleven women (22 ovaries) were examined on day 8 of controlled ovarian hyperstimulation therapy, which was part of their in vitro fertilization treatment protocol. The patients were exam...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید