نتایج جستجو برای: non lead shielding garments

تعداد نتایج: 1619493  

Journal: :iranian journal of radiation research 0
f. bouzarjomehri shahid sadoughi university of medical sciences, yazd, iran m. kiani tabriz university of medical sciences, medical physics, tabriz, iran a.r. farajollahi tabriz university of medical sciences, medical physics, tabriz, iran

background: the shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. these methods include lead standard blocks, individual molding and multi leaf collimator (mlc). the mlc method is not still common in iran radiotherapy centers. individual molding is better than the lead block shield...

Journal: :journal of biomedical physics and engineering 0
a r farajollahi f bouzarjomehri m kiani

normal 0 false false false en-us x-none fa introduction: in radiation therapy centers across iran, protection of normal tissues is usually accomplished by either cerrobend or lead block shielding. in this study, the influence of these two shielding methods on central axis dose distribution of photon beam a cobalt unit was investigated in clinical conditions. materials and methods: all measureme...

2015
A. Arun Senthil Kumar

Layout design and the flow of materials have a significant impact on performance of manufacturing system (garments industry) .These can help to increase productivity, reduce work in process and inventory, short production lead time, streamlines the flow of materials, cost and reduce non value added activities from the production process of waiting and transportation, which make the factory meet...

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

A R Farajollahi, F Bouzarjomehri M Kiani,

Introduction: In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions. Materials and Methods: All measurements were performed for 60Co γ-ray beams an...

Shielding radiation from both x-rays and gamma-rays is important for personnel in medical fields e.g. interventional radiology, nuclear power stations, and other inspection facilities where radiation is involved. Lead is known for its effective shielding property against these high energy radiations, however heaviness and toxicity are its main drawback. In this study effectiveness of non-lead p...

2017
Shuxu Zhang Shaohui Jiang Quanbin Zhang Shengqu Lin Ruihao Wang Xiang Zhou Guoqian Zhang Huaiyu Lei Hui Yu

With the purpose of reducing stray radiation dose (SRD) in out-of-field region (OFR) during radiotherapy with 6 MV intensity-modulated radiation therapy (IMRT), a body-shielding device (BSD) was prepared according to the measurements obtained in experimental testing. In experimental testing, optimal shielding conditions, such as 1 mm lead, 2 mm lead, and 1 mm lead plus 10 mm bolus, were investi...

Journal: Nanomedicine Journal 2020
Mohammad Yousefi Sooteh Parinaz Mehnati, Reza Malekzadeh,

composites with micro- and nano-metal fillers has attracted the attention of researchers for radiation shielding applications. Lead toxicity and heaviness have oriented extensive research toward the use of non-lead composite shields. The present study aimed to systematically review the efficiency of the composite shields of various micro- and nano-sized materials as composite shields have been ...

Journal: :The British journal of radiology 1976
F M Khan V C Moore S H Levitt

In the treatment of superficial lesions with 8-13 MeV electrons, lead shields are often used to protect the underlying tissue. Measurements were made with film and ion chamber to analyse various aspects of external and internal shielding in electron beam therapy. Data were obtained on the thickness of lead required for shielding, the effect of blocking on dose-rate, electron-backscattering from...