Journal: :Analytical methods : advancing methods and applications 2013
Michael J Caspers Todd D Williams Kimberly M Lovell Anthony Lozama Eduardo R Butelman Mary Jeanne Kreek Matthew Johnson Roland Griffiths Katherine Maclean Thomas E Prisinzano

A facile method for quantifying the concentration of the powerful and widely available hallucinogen salvinorin A (a selective kappa opioid agonist) from non-human primate cerebrospinal fluid (CSF) and human plasma has been developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization (ESI) mode. With CSF solid phase extraction can be avoided compl...

Journal: :Journal of pharmaceutical and biomedical analysis 2014
Róbert Kormány Jenő Fekete Davy Guillarme Szabolcs Fekete

The goal of this study was to evaluate the accuracy of simulated robustness testing using commercial modelling software (DryLab) and state-of-the-art stationary phases. For this purpose, a mixture of amlodipine and its seven related impurities was analyzed on short narrow bore columns (50×2.1mm, packed with sub-2μm particles) providing short analysis times. The performance of commercial modelli...

Journal: :Clinical chemistry 1996
J B Pappas E M Allen M Ross W Banner

Amrinone (AMR), a bipyridine derivative, is receiving increasing use in postoperative cardiac patients as an inotrope and vasodilator. The hemodynamic response to amrinone in adults is linearly related to AMR concentrations, warranting therapeutic drug monitoring. We report a rapid microsample HPLC method for monitoring AMR and its principal metabolites, N-acetyl (N-ac) and N-glycolyl (N-gly) A...

2016

Submit Manuscript | http://medcraveonline.com bioactive, and their use could be diverted towards either in the animal feed production, or to the recovery of purified molecules for nutraceutical purposes. Since they occur in complex mixture for their analyses a very advanced analytical liquid chromatography technique was employed. Such a technique is called ccomprehensive two-dimensional liquid ...

Journal: :The Analyst 2000
D Blanco M P Fernández M D Gutiérrez

A reversed-phase high-performance liquid chromatographic method is described for the simultaneous determination of vitamins A, D2, D3, E and K1, retinyl acetate, retinyl palmitate, tocopherol acetate, ergosterol and 7-dehydrocholesterol in milk and butter. Narrow-bore columns are recommended because this alternative provides a good separation and efficiency, plus greater economy and sensitivity...

Journal: :Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 2004
Esther Forgács Tibor Cserháti Ivan Miksik Adam Echardt Zdenek Deyl

The retention time of 22 barbituric acid derivatives was measured on a narrow-bore porous graphitized carbon (PGC) column using water-dioxane mixtures as mobile phases. The capacity factor (k), theoretical plate number (N), and asymmetry factor (AF) were calculated for each solute in each mobile phase. The relationships between chromatographic characteristics and physicochemical parameters of s...

2011
Tibor Cserháti Maria Szőgyi

The retention time of 23 barbituric acid derivatives was determined on an narrow-bore porous graphitized carbon (PGC) column employing water-dioxane mixtures as mobile phases. The retention factor (k), theoretical plate number (N), and asymmetry factor (AF) were computed for each analyte in each mobile phase. Quantitative structure-retention relationship (QSRR) calculations using stepwise regre...

2008
Andrea Hercegová Eva Matisová

Possibilities and limitations of a bench top mass spectrometric detector (MSD) in selective ion monitoring mode (SIM) and electron capture detector (ECD) in fast gas chromatography (GC) with narrow bore columns of samples with complex matrices at ultra trace levels of pesticide residues were studied and compared.. Various injection systems were searched (splitless, on-column, programmable tempe...