نتایج جستجو برای: metal bracket

تعداد نتایج: 201573  

Mohammad Ghorbani, Soodeh Tahmasbi, Tahereh Sheikh, Yadollah Yaghoubnejad,

  Objective: Corrosion resistance is among the most important properties of metal alloys used in the oral cavity. Consumption of acidic foods reduces the salivary pH and intensifies the corrosion of brackets and orthodontic wires. This study aimed to compare electro galvanic corrosion of different orthodontic brackets and wires and determine the amount of ions released into acidic artifici...

2004
David M. Adams

Beam theory was used to evaluate the stiffness of a simulated orthodontic model as affected by the type of bracket, interbracket distance, type of ligature tie, and size of segment. For a given deflection, the model generated greater force (increased stiffness) as the beam constant (N) increased. N increased as interbracket distance increased. Metal ties were as rigid or more rigid than o-rings...

Journal: :dental research journal 0
shiva alavi navid hosseini

background: properties of coated archwires, which have been introduced for esthetic demands during orthodontic treatments, along with the use of tooth-colored brackets, are not clear. the aim of this study is to compare the load-deflection and surface properties of coated superelastic archwires with conventional superelastic archwires in conventional and metal-insert ceramic brackets. materials...

2017
Pillai Devu Radhakrishnan N. K. Sapna Varma V. V. Ajith

OBJECTIVE The objective of this study was to compare the surface morphology and dimensional stability of the bracket slot at the onset of treatment and after 12 months of intraoral exposure. The study also compared the amount of calcium at the bracket base which indicates enamel loss among the three orthodontic brackets following debonding after 12 months of intraoral exposure. MATERIALS AND ...

Journal: :journal of dental school, shahid beheshti university of medical sciences 0
سوده طهماسبی soodeh tahmasbi dental school, shahid beheshti university of medical sciences, tehran-iran.، دانشکده دندانپزشکی، دانشگاه علوم پزشکی شهید بهشتی. محمد قربانی mohammad ghorbani sharif university of technilogyدانشکده مهندسی مواد، دانشگاه صنعتی شریف. طاهره شیخ tahereh sheikh یدا... یعقوب نژاد yadollah yaghoubnejad sharif university of technilogyدانشکده مهندسی مواد، دانشگاه صنعتی شریف.

objective: corrosion resistance is among the most important properties of metal alloys used in the oral cavity. consumption of acidic foods reduces the salivary ph and intensifies the corrosion of brackets and orthodontic wires. this study aimed to compare electro galvanic corrosion of different orthodontic brackets and wires and determine the amount of ions released into acidic artificial sali...

Journal: :European journal of orthodontics 2011
Jun Li

Three types of experimental resin cements with different curing systems, dual, light, and chemical, were designed. The relationship between the flexural strengths of the three experimental and five commercial (Beauty Ortho Bond, Transbond™ XT, Light Cure Bond, Kurasper® F, and Super Bond) orthodontic resin cements on the tensile bond strength (TBS) and shear bond strength (SBS) of metal bracket...

2016
Hee-Min Lee Sang-Cheol Kim Kyung-Hwa Kang Na-Young Chang

OBJECTIVE With the introduction of third-generation light-emitting diodes (LEDs) in dental practice, it is necessary to compare their bracket-bonding effects, safety, and efficacy with those of the second-generation units. METHODS In this study, 80 extracted human premolars were randomly divided into eight groups of 10 samples each. Metal or polycrystalline ceramic brackets were bonded on the...

Journal: :European journal of orthodontics 1999
L Fernandez J A Canut

Tensile bond strength and bond failure location were evaluated in vitro for two types of aesthetic brackets (non-silanated ceramic, polycarbonate) and one stainless steel bracket, using bovine teeth as the substrate and diacrylate resin as the adhesive. The results show that metallic bracket had the highest bond strength (13.21 N) followed by the new plastic bracket (12.01 N), which does not re...

Journal: :American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics 2004
Clarice Nishio Andréa Fonseca Jardim da Motta Carlos Nelson Elias José Nelson Mucha

The aim of this study was to evaluate the frictional force between orthodontic brackets and archwires. The differences in magnitude of the frictional forces generated by ceramic brackets, ceramic brackets with metal reinforced slot, and stainless steel brackets in combination with stainless steel, nickel-titanium, and beta-titanium orthodontic archwires were investigated. Brackets and wire were...

2015
P C Sunil Tony Michael Aravind S Raju Renji K Paul J Mamatha T M Ebin

BACKGROUND The objective of the study was to determine the sites of plaque accumulation and to compare the plaque accumulated with metal and self-ligating orthodontic brackets in order to know which bracket type had a higher plaque retaining capacity. MATERIALS AND METHODS The study was done on 20 subjects who were scheduled for orthodontic treatment including extraction of four premolars and...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید