نتایج جستجو برای: magic f polymer gel dosimeters

تعداد نتایج: 505330  

Journal: :Applied sciences 2021

Much of the complex medical physics work requires radiation dose delivery, which dosimeters to accurately measure three-dimensional distribution with good spatial resolution. MAGIC-f polymer gel is one emerging new widely used in research. The purpose this study was present an overview dosimetry, using gel, including its composition, manufacture, imaging, calibration, and application In review,...

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

اربابی, عظیم, بلوری, بهرام, ندایی, حسن, قهرمان اصل, روح اله,

  Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...

Ahmad Farahani Behrooz Reafie Hassan Hashemi Leaila Karimi-Afshar Mahmoud Allahverdi, Mohammadreza Ay Morteza Bakhteiari Nader Riahi Alam Tayeb Alahverdi purfallah

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

Azim Arbabi Hossein Masoumi Manijeh Mokhtari-Dizaji Mohsen Bakhshandeh

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiat...

ژورنال: سنجش و ایمنی پرتو 2020

In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...

Journal: :iranian journal of medical physics 0
hadis ansari mehr1 department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...

2015
H. Khosravi B. Hashemi S. R. Mahdavi P. Hejazi

BACKGROUND Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. OBJECTIVE The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radioth...

2017
M. Keshtkar M.H. Zahmatkesh A.R. Montazerabadi

BACKGROUND Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin In...

R. Jafari Khalilabadi, S. Aftabi, S.M. Abtahi,

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید