نتایج جستجو برای: magic f polymer gel dosimeter
تعداد نتایج: 505553 فیلتر نتایج به سال:
Introduction: Normoxic MAGIC-f polymer gels are established dosimeters used for three dimensional dos uantifications in radiotherapy. The high atomic number nanoparticles such as gold are nov adiosensitizers used to enhance doses delivered to tumors. The aim of this study was t vestigate the effect of gold nanoparticles (GNPs) in enhancing percentage depth doses (PDD ithin the...
Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiat...
In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...
introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...
introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...
background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere a...
Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید