Our institution performs in vivo verification measurement for each of our total body irradiation (TBI) patients with optically stimulated luminescent dosimeters (OSLD). The lung block verification measurements were commonly higher than expected. The aim of this work is to understand this discrepancy and improve the accuracy of these lung block verification measurements. Initially, the thickness...

Journal: :international journal of pediatrics 0
vahid karami department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, iran mansour zabihzadeh department of medical physics, school of medicine, student research committee, ahvaz jundishapur university of medical sciences, ahvaz, iran. department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, iran amir danyaei department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, iran. nasim shams department of oral and maxillofacial radiology, school of dentistry, ahvaz jundishapur university of medical sciences, ahvaz, iran

background: increasing the x-ray focus to film distance (ffd) has been advocated as an effective method to reduce the patients’ radiation dose. the aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.material and methods: sixty pediatric patients were x-ray imaged at ffds of 100 and 130 cm. dose measurements were ...

Journal: :Acta orthopaedica Belgica 2012
Ishrat A Khan Senthil Kamalasekaran M Ali Fazal

We undertook this study to determine the amount of scattered radiation received by the primary surgeon, assistant and patient during dynamic hip screw fixation for proximal femoral fractures. Data was collected from fifty patients. Five registrars were included as operating surgeon and four senior house officers as assistant surgeon. Radiation was monitored by thermo luminescent dosimeters plac...

2017
E. Tchistiakova A. Kim W. Y. Song G. Pang

Magnetic resonance imaging (MRI) is being rapidly integrated for cancer treatments-such systems are referred to as MRI-guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of a strong static magnetic field from the MRI scanner during radiotherapy delivery presents new challenges. One of the challenges is that a personal radiation dosimeter used to estima...

2009
C. Cosma Alida Timar V. Benea T. Jurcut D. Ciorba

The main trend in radiation dosimetry nowadays is the use of solid state detectors. Luminescent dosimetric techniques are part of this field. This paper aims to present the application of thermoluminescence as a tool in measuring natural nuclear radiation, namely the application of highly sensitive sintered dosimeters MCP-N (LiF:Mg,Cu,P) in environmental monitoring and the possibility of using ...

Journal: :Medical physics 2007
Paul A Jursinic

Optically stimulated luminescent dosimeters, OSLDs, are plastic disks infused with aluminum oxide doped with carbon (Al2O3 : C). These disks are encased in a light-tight plastic holder. Crystals of Al2O3 : C when exposed to ionizing radiation store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence dep...

2014
Mariagabriella Pugliese Filomena Loffredo Maria Quarto Vincenzo Roca Gianna Vivaldo Alba Zanini

The assessment of space radiation exposure on plants, animals, cell cultures, as well as the astronauts, is crucial not only because it is very different from that to which they are subjected on the earth, but also to understand the combined effects of exposure to space radiation under microgravity. In particular, we evaluated the equivalent dose due to neutrons and charged particles for biolog...

Journal: :Physics in medicine and biology 2011
I Mrčela T Bokulić J Izewska M Budanec A Fröbe Z Kusić

A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...