نتایج جستجو برای: locking

تعداد نتایج: 12034  

Journal: :amirkabir international journal of electrical & electronics engineering 2015
a. tofangdarzade a. jalali

in this work, time domain analysis is used to solve adler’s equation in order to obtain the required time, for an oscillator under external injection, reaching the steady-state condition. mathematical approach has been applied to fully describe the transient of frequency acquisition in injection-locked lc and ring oscillators considering their time-varying nature. then, the analysis is verified...

2000
Patrick O'Neil Alan Fekete Elizabeth O'Neil Dimitrios Liarokapis

We discuss three forms of phantom prevention locking that have been proposed in the literature: (1) predicate locking [EGLT76], (2) precision locking [JBB81], and (3) index locking (specifically, KVL/IM locking [MOHAN90, MOHAN92, MOHAN96]). The predicate locking method was dropped from consideration in System R because of perceived problems [CHETAL81]. The precision locking technique was propos...

Journal: :archives of trauma research 0
kavin khatri department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india; department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india. tel: +91-8743878077 vijay sharma department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india kamran farooque department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india vivek tiwari department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india

conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...

Journal: :the archives of bone and joint surgery 0
seyyed morteza kazemi bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran reza minaei bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran farshad safdari bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran ali keipourfard akhtar hospital, shahid beheshti university of medical sciences, tehran, iran rozhin forghani bone joint and related tissue research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, iran alemeh mirzapourshafiei clinical research development center, babol university of medical sciences, babol, iran

background: there are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. in the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. methods: forty patients with valgus knee malalignment were randomly assigned to two equal numb...

1999
Douglas C. Schmidt

Example Commercial Web servers typically maintain a ‘hit count’ component that records how many times each URL is accessed by clients over a period of time. To reduce latency, a Web server process does not maintain the hit counts in a file on disk but rather in a memoryresident table. Moreover, to increase throughput, Web server processes are often multi-threaded [HS98]. Therefore, public metho...

2017
Marcos K. Aguilera Tudor David Rachid Guerraoui

We present multiversion timestamp locking (MVTL), a new genre of multiversion concurrency control algorithms for serializable transactions. The key idea behind MVTL is simple and novel: lock individual time points instead of locking objects or versions. After showing what a generic MVTL algorithm looks like, we demonstrate MVTL’s expressiveness: we present several simple MVTL algorithms that ad...

2015
K Pandey C Sah

Injection locking characteristics of oscillators are reviewed both theoretically and experimentally. Theoretical results coupled with experimental findings are presented. A simple method of deriving the equation for locking range is reported.

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تحصیلات تکمیلی صنعتی کرمان - پژوهشکده برق و کامپیوتر 1390

a phase-locked loop (pll) based frequency synthesizer is an important circuit that is used in many applications, especially in communication systems such as ethernet receivers, disk drive read/write channels, digital mobile receivers, high-speed memory interfaces, system clock recovery and wireless communication system. other than requiring good signal purity such as low phase noise and low spu...

Journal: :Orthopedics 2013
Shan-Wei Yang Shyh Ming Kuo Shwu Jen Chang Tian-Shiang Su Hsiang-Ho Chen Jenn-Huei Renn Ting-Sheng Lin

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking ...

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید