Modern power system networks use active power filters for compensation of harmonic currents generated by non linear loads. In this paper a new method for generating reference currents for harmonic and reactive power compensation is proposed. The proposed method has the advantage that it generates the reference currents irrespective of the supply voltage and load conditions. So the source has to...
In this paper, a 3-phase active power filter (APF) is presented to eliminate harmonics and to compensate the reactive power of an uncontrolled rectifier with capacitive loading taken as non-linear load. An APF is realized using 3-phase voltage source inverter (VSI) with dc bus capacitor. Reference source currents are estimated using P-I control over dc bus voltage and 3-phase source voltages. C...
This paper presents a novel way of generating the reference currents for an active filter and/or a static compensator. A compensator structure is proposed which is capable of balancing an unbalanced delta-connected load that may also draw harmonic currents. In addition to balancing the load, the supply side power factor is also made unity. The theory of instantaneous symmetrical components is u...
This paper proposes a new method of sliding mode base controller for shunt active power filter to compensate the harmonic currents of a load. In this controller there isn't any need to PI DC voltage controller to regulate the DC capacitor voltage of shunt active power filter. In this method, first the reference currents of shunt active power filter that should be tracked to reduce or eliminate ...
Dc-dc converters suitable for use in battery-powered electronic equipment with energy management are discussed. To realize the benefits of energy management, these converters must be capable of maintaining regulation of their output voltages at no load, while maintaining high efficiency. Variable frequency operation is shown to give an improvement in efficient operating range of approximately t...
Class-AB circuits, which are able to deal with currents several orders of magnitude larger than their quiescent current, are good candidates for low-power and high slew-rate analog design. This paper presents a novel topology of a class AB flipped voltage follower (FVF) that has better slew rate and the same power consumption as the conventional class-AB FVF buffer previously presented in liter...
Conventional fault location methods using voltages and currents of one terminal are not applicable to multiterminal transmission lines. So far some techniques have been presented to solve fault location problem for multi-terminal transmission lines. In these methods, lumped or distributed frequency domain models of transmission lines have been used. In multi terminal lines, faulty section shoul...
Due to inherent time delays in the control system of Hybrid Active Power Filter with Injection Circuit (IHAPF) and the load harmonic currents changes rapidly and dramatically. In order to eliminate these harmonic currents, an IHAPF to be used must be able to respond quickly following variable of the harmonic currents. So, this paper proposes a PID-fuzzy control method with time-delay compensati...
Stray load loss refers generally to the sources of induction machine loss not accounted for by typical calculations of primary or secondary copper loss, no load core loss, or friction and windage loss. Harmonic rotor bar currents from the non-sinusoidal distribution of the slotted stator winding contribute significant stray load loss. Rotor bars, especially on cast rotors for machines under fif...