نتایج جستجو برای: k ion selective electrodes

تعداد نتایج: 782912  

Journal: :Physical review letters 2013
P Bushev G Hétet L Slodička D Rotter M A Wilson F Schmidt-Kaler J Eschner R Blatt

We perform a high-resolution real-time readout of the motion of a single trapped and laser-cooled Ba+ ion. By using an interferometric setup, we demonstrate a shot-noise-limited measurement of thermal oscillations with a resolution of 4 times the standard quantum limit. We apply the real-time monitoring for phase control of the ion motion through a feedback loop, suppressing the photon recoil-i...

Journal: :Nanoscale 2014
Hyungjin Lee Donghwa Lee Yumi Ahn Eun-Woo Lee Lee Soon Park Youngu Lee

Highly flexible and efficient silver nanowire-based organic light-emitting diodes (OLEDs) have been successfully fabricated by employing a n-type hole injection layer (HIL). The silver nanowire-based OLEDs without light outcoupling structures exhibited excellent device characteristics such as extremely low turn-on voltage (3.6 V) and high current and power efficiencies (44.5 cd A(-1) and 35.8 l...

Journal: :Clinical chemistry 1980
P Fievet A Truchaud J Hersant G Glikmanas

We tested the response of ion-selective sodium and potassium electrodes that are a part of the new multi-channel chemical analyzers, Astra 8 and Astra 4 (Beckman). For this we used plain and albumin-containing aqueous solutions of known Na+ and K+ concentrations, varied inversely so we could assess how the concentration of each electrolyte would affect the response of the other electrode. The s...

Journal: :Acta poloniae pharmaceutica 2006
Joanna Lenik Cecylia Wardak Barbara Marczewska

The composition of a polymeric potential-determining phase for ketoprofen selective electrode has been determined and the following basic electrode parameters were examined: measurement range, slope characteristic, limit of detection, response time, lifetime and selectivity coefficients in relation to some organic and inorganic anions. The electrode have been used for ketoprofen determination i...

2017
Marta Haro Vidyadhar Singh Stephan Steinhauer Evropi Toulkeridou Panagiotis Grammatikopoulos Mukhles Sowwan

A new approach on the synthesis of Si anodes for Li-ion batteries is reported, combining advantages of both nanoparticulated and continuous Si films. A multilayered configuration prototype is proposed, comprising amorphous Si arranged in nanostructured, mechanically heterogeneous films, interspersed with Ta nanoparticle scaffolds. Particular structural features such as increased surface roughne...

Journal: :The Analyst 2010
Manoj Kumar Abhimanew Dhir Vandana Bhalla Richa Sharma Rajiv Kumar Puri Rakesh Kumar Mahajan

A new bispyrenyl azadiene derivative has been synthesized and examined for its cation recognition abilities toward different cations. The ligand shows strong affinity for Hg(2+) ions over other cations such as Cu(2+), Pb(2+), Zn(2+), Ni(2+), Cd(2+), Ag(+), K(+), Na(+) and Li(+). An "Off-On" type of fluorescent behaviour was observed with simultaneous presence of Cu(2+) and Hg(2+) ions. An ion s...

Journal: :physical chemistry and electrochemistry 0

2-amino-n-benzthioazolyl benzamide (abtb) was synthesized, characterized and used for thefabrication of a potentiometric sensor for cu2+ metal ions. the electrode exhibits linear response to cu(ii) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 m) with nernstian slope of 30 ± 1.5 mvper decade. the electrode can be used in the ph range from 2 to 9. it has a fast response time of about1...

Journal: :Caries research 2011
E A Martínez-Mier J A Cury J R Heilman B P Katz S M Levy Y Li A Maguire J Margineda D O'Mullane P Phantumvanit A E Soto-Rojas G K Stookey A Villa J S Wefel H Whelton G M Whitford D T Zero W Zhang V Zohouri

BACKGROUND/AIMS Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. METHODS A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then revie...

Journal: :Journal of Chemical Education 1974

2013

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید