نتایج جستجو برای: ion selective electrodes

تعداد نتایج: 429332  

Journal: :Acta poloniae pharmaceutica 2006
Joanna Lenik Cecylia Wardak Barbara Marczewska

The composition of a polymeric potential-determining phase for ketoprofen selective electrode has been determined and the following basic electrode parameters were examined: measurement range, slope characteristic, limit of detection, response time, lifetime and selectivity coefficients in relation to some organic and inorganic anions. The electrode have been used for ketoprofen determination i...

2017
Marta Haro Vidyadhar Singh Stephan Steinhauer Evropi Toulkeridou Panagiotis Grammatikopoulos Mukhles Sowwan

A new approach on the synthesis of Si anodes for Li-ion batteries is reported, combining advantages of both nanoparticulated and continuous Si films. A multilayered configuration prototype is proposed, comprising amorphous Si arranged in nanostructured, mechanically heterogeneous films, interspersed with Ta nanoparticle scaffolds. Particular structural features such as increased surface roughne...

Journal: :The Analyst 2010
Manoj Kumar Abhimanew Dhir Vandana Bhalla Richa Sharma Rajiv Kumar Puri Rakesh Kumar Mahajan

A new bispyrenyl azadiene derivative has been synthesized and examined for its cation recognition abilities toward different cations. The ligand shows strong affinity for Hg(2+) ions over other cations such as Cu(2+), Pb(2+), Zn(2+), Ni(2+), Cd(2+), Ag(+), K(+), Na(+) and Li(+). An "Off-On" type of fluorescent behaviour was observed with simultaneous presence of Cu(2+) and Hg(2+) ions. An ion s...

Journal: :physical chemistry and electrochemistry 0

2-amino-n-benzthioazolyl benzamide (abtb) was synthesized, characterized and used for thefabrication of a potentiometric sensor for cu2+ metal ions. the electrode exhibits linear response to cu(ii) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 m) with nernstian slope of 30 ± 1.5 mvper decade. the electrode can be used in the ph range from 2 to 9. it has a fast response time of about1...

Journal: :Caries research 2011
E A Martínez-Mier J A Cury J R Heilman B P Katz S M Levy Y Li A Maguire J Margineda D O'Mullane P Phantumvanit A E Soto-Rojas G K Stookey A Villa J S Wefel H Whelton G M Whitford D T Zero W Zhang V Zohouri

BACKGROUND/AIMS Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. METHODS A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then revie...

Journal: :Journal of Chemical Education 1974

2013

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...

2005

Methods for the determination of fluorine in a variety of matrices are reviewed with particular attention to those techniques which are widely adopted as routine methods. The fluoride ion-sensitive electrode is a very successful potentiometric technique for the determination of fluoride in aqueous solution and it has largely replaced the various colorimetric methods formerly used. However it is...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشکده علوم پایه 1388

چکیده ندارد.

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید