Introduction: One of the useful standard quality assurance techniques in radiation therapy is monitoring entrance doses in in-vivo dosimetry. An overall tolerance limit of 5% of the absorbed radiation dose has been recommended by the International Commission of Radiological Units. The implementation of an in vivo dosimet...

2017
Stefano Peca Richie Siddhartha Sinha Derek Wilson Brown Wendy Lani Smith

PURPOSE We recently developed a novel, open-source in vivo dosimetry that uses the electronic portal imaging device to detect dose delivery discrepancies. We applied our method on patients with rectal cancer treated on a belly board device. METHODS In vivo dosimetry was performed on 10 patients with rectal cancer treated prone on the belly board with a 4-field box arrangement. Portal images w...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2014
G Gambarini M Carrara C Tenconi N Mantaut M Borroni D Cutajar M Petasecca I Fuduli M Lerch E Pignoli A Rosenfeld

MOSkin detectors were studied to perform real-time in vivo dose measurements in high dose rate prostate brachytherapy. Measurements were performed inside an urethral catheter in a gel phantom simulating a real prostate implant. Measured and expected doses were compared and the discrepancy was found to be within 8.9% and 3.8% for single MOSkin and dual-MOSkin configurations, respectively. Result...

2014
Magdalena Fundowicz Miguel Macia Susanna Marin Marta Bogusz-Czerniewicz Ewelina Konstanty Ignaci Modolel Julian Malicki Ferran Guedea

BACKGROUND We performed a clinical audit of preoperative rectal cancer treatment at two European radiotherapy centres (Poland and Spain). The aim was to independently verify adherence to a selection of indicators of treatment quality and to identify any notable inter-institutional differences. METHODS A total of 162 patients, in Catalan Institute of Oncology (ICO) 68 and in Greater Poland Can...

abbas haghparast, Mahdi Mohammadi Razieh Zaghian

Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...

Ali Jomehzadeh, Alireza Amouheidari Anton Mans Ben Mijnheer Mohammad Mohammadi, Parvaneh Shokrani

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

مهدوی, ربیع, رضائی جو, مسعود, هاشمی, بیژن ,

Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The stu...

Journal: :Radiation Measurements 2007

2016
Jaden D. Evans Laura L. Haley Sarah E. Locher Michael P. Grams Christopher L. Deufel John A. Antolak James A. Martenson

Total skin electron irradiation (TSEI) is an effective option for cutaneous T-cell lymphoma (CTCL). Two conventional methods used to deliver TSEI are the Stanford multiple dual field technique and the McGill rotational technique; however, both techniques require patients to stand for 10 to 30 minutes and cannot be used in nonambulatory patients. Our group has previously described technical para...