نتایج جستجو برای: external fixator

تعداد نتایج: 190631  

Journal: :archives of trauma research 0
hossein aslani pediatric orthopedic, tehran university of medical sciences,tehran, ir iran ali tabrizi orthopedic surgery, shohada educational hospital, tabriz university of medical sciences, tabriz, ir iran; orthopedic surgery, shohada educational hospital, tabriz university of medical sciences, tabriz, ir iran. tel:+98-9148883851 ali sadighi shohada educational hospital, tabriz university of medical sciences, tabriz, ir iran ahmad reza mirblok orthopedic surgery, poursina educational hospital, guilan university of medical sciences, rasht, ir iran

conclusions although external fixation in open pediatric fractures and severe injuries is recommended, intramedullary nailing is also an effective method with low complications. combining pins and flexible intramedullary nails is effective in developing more stability and is not associated with more complications. background tibial fractures are the third most common pediatric long-bone fractur...

Journal: :iranian journal of medical sciences 0
saaid tabatabai e. hosseini

background: the treatment of open tibial fractures is still an orthopaedic challenge and full of complications. in many cases the use of external fixator that has been known as a non-:union: machine is obligatory with a high incidence of pin track infection and other complications. the aim of this study was to compare the use of external fixation as a definite method for treatment of open tibia...

Journal: :Injury 2015
Catherine Logan Arthur Hess John Y Kwon

INTRODUCTION To evaluate relative cost of external fixator constructs applied for damage control purposes in a cohort of advanced orthopaedic trainees and orthopaedic staff traumatologists. We also sought to evaluate physicians' understanding of component cost. MATERIALS AND METHODS Participants were asked to apply an external fixator for three separate fracture patterns in damage control fas...

Journal: :Medicinski arhiv 2011
Predrag Grubor Milan Grubor Mithat Asotic

UNLABELLED Stabilization of fractures by external fixator is based on the mechanical connecting of the pins, screwed into the proximal and distal bone fragment. Site of fracture is left without any foreign materials, which is essential for prevention of infections. Aim of this work is to compare stability of constructs bone model-external fixators of different types (Ortofix, Mitković, Charnele...

E. Hosseini Saaid Tabatabai,

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

Journal: :bulletin of emergency and trauma 0
sarabjeet kohli mgm medical college, navi mumbai vikram khanna national institute of medical sciences, jaipur nilesh virani mgm medical college, navi mumbai hemant chaturvedi national institute of medical sciences, jaipur

carpal injuries are uncommon and are mainly seen in the younger age group. the incidence is unclear as many of the cases go undiagnosed. a 22-year-old male patient coming to the hospital after road traffic accident with head, face and left wrist injury. after immediate primary management the patient was taken up for a definitive procedure 4 days after the injury. scaphoid fracture was fixed wit...

Journal: :Collegium antropologicum 2014
Bojan Bukva Goran Vrgoc Radivoj Brdar Sinisa Ducić Gordan Gulan Hari Jurdana

The purpose of this study was to evaluate the influence of intramedullary (IM) alignment used in combination with an Ilizarov external fixation on the healing index (HI) and lengthening index (LI) in the treatment of congenital leg length discrepancies (LLD). This study included 35patients aged from 3.5 to 19 (average age 10.73) who underwent thl egalisation procedure using an Ilizarov external...

Journal: :The Medical journal of Malaysia 1992
O Masbah M A Noor

The results of treatment using a locally-designed external fixator in 20 patients are presented. Open fractures were the main indications for external fixation. Pin tract infection occurred in 8 patients. Only 2 patients had unstable fixation which required removal of the device. One third of patients developed malunion exceeding 15 degrees and two thirds had joint stiffness after conversion to...

Journal: :SICOT-J 2015
Ali S Bajwa Manju Rammappa Ling Lee Rajesh Nanda

INTRODUCTION Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. AIMS To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate co...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید