Journal: :Medical physics 2013
Anna Fredh Jonas Bengtsson Scherman Lotte S Fog Per Munck af Rosenschöld

PURPOSE The purpose of the present study was to investigate the ability of commercial patient quality assurance (QA) systems to detect linear accelerator-related errors. METHODS Four measuring systems (Delta(4®), OCTAVIUS(®), COMPASS, and Epiqa™) designed for patient specific quality assurance for rotational radiation therapy were compared by measuring four clinical rotational intensity modul...

Journal: :Actas dermo-sifiliograficas 2018
S Requena López Y Hidalgo García S Gómez Díez B Vivanco Allende

1. Rossi R, Mori M, Lotti T. Actinic keratosis. Int J Dermatol. 2007;46:895--904. 2. Schaefer I, Augustin M, Spehr C, Reusch M, Kornek T. Prevalence and risk factors of actinic keratoses in Germany----analysis of multisource data. J Eur Acad Dermatol Venereol. 2014;28:309--13. 3. Naldi L, Chatenoud L, Piccitto R, Colombo P, Placchesi EB, La Vecchia C, et al. Prevalence of actinic keratoses and ...

2018
C. Ferrándiz-Pulido M. Lera-Imbuluzqueta C. Ferrándiz M. J. Plazas-Fernandez

1. Rossi R, Mori M, Lotti T. Actinic keratosis. Int J Dermatol. 2007;46:895--904. 2. Schaefer I, Augustin M, Spehr C, Reusch M, Kornek T. Prevalence and risk factors of actinic keratoses in Germany----analysis of multisource data. J Eur Acad Dermatol Venereol. 2014;28:309--13. 3. Naldi L, Chatenoud L, Piccitto R, Colombo P, Placchesi EB, La Vecchia C, et al. Prevalence of actinic keratoses and ...

2016
P. Fenoglietto M. Khodri D. Nguyen F. Josserand-Pietri N. Aillères

PURPOSE To verify the accuracy of volumetric arc therapy (VMAT) using the RapidArc™ device when switching patients from one single linear accelerator (linac) to a paired energy and mechanics "twin" linac without reoptimization of the original treatment plan. PATIENTS AND METHODS Four centers using 8 linacs were involved in this study. Seventy-four patients previously treated with the 6MV phot...

2012
Krishna Murthy

Purpose: To validate a locally fabricated phantom of Imatrixx-2D Array by comparing its results with ArcCheck phantom and comparing portal dosimetry measurements with the two phantom studies. Materials and Methods: Electronic Portal Imaging Devices and Epiqa software were used for portal dosimetry. An Imatrixx-2D array with a locally fabricated phantom and ArcCheck cylindrical phantom were used...