نتایج جستجو برای: endotracheal tube defect

تعداد نتایج: 192885  

Journal: :iranian journal of neonatology 0
seyedeh fatemeh khatami department of pediatric, devision of neonatology, tehran university of medical sciences, iran pouya parvaresh department of internal medicine, faculty of medical sciences szeged, medical university szeged, hungary shahin behjati department of pediatric, devision of neonatology, tehran university of medical sciences, iran

objective the purpose of this study was to assess the frequency of complications of endotracheal intubation (eti) in neonates. methods the newborns that were admitted and needed urgent or semi-urgent intubation were enrolled in this study over a 1 year period. route for intubation in all cases were orotracheal. cases were not routinely sedated or paralyzed. the patients were clinically and radi...

Hamid Haghani, Mahnaz Seyedoshohadaee, Mansoureh Ashghali farahani, Shakeh Hagnazarian,

Background: The unplanned departure of endotracheal tube is one of the main complications for endotracheal intubation. In addition to endotracheal extubation, its movement can also lead to damage to the oral cavity. Stabilizing endotracheal tube is the most important factor that can prevent unplanned departure of endotracheal tube as well as its movement. The current study was done with the aim...

Journal: :iranian journal of pathology 2009
maryam amini ahmad javanmard ali davati ghasem azimi

background and objectives: nosocomial infections are one of the most important worldwide health and increased patients hospital stay, therapeutic problem and mortality rate. this study was designed to determine the frequency of microorganisms isolated from tracheal tube in patients admitted to icu shaheed mostafa khomeini hospital tehran, iran, from 2001-2005. patients and methods: in this cros...

Journal: :Southern African Journal of Anaesthesia and Analgesia 2015

Journal: :iranian journal of nursing and midwifery research 0
nazanin amini korosh rezaei ahmadreza yazdannik

abstract background: formation of biofilm and bacterial colonization within the endotracheal tube (ett) are significant sources of airway contamination and play a role in the development of ventilator-associated pneumonia (vap). this study was conducted to examine the effect of nebulized eucalyptus (ne) on bacterial colonization of ett biofilm. materials and methods: we performed a randomized c...

Journal: :British heart journal 1987
A M Harris S Shawkat J S Bailey

A reinforced cuffed endotracheal tube was used to drain blood from a left superior vena cava via the coronary sinus during patch repair of a sinus venosus defect in a 65 year old patient. This approach produced good drainage and a bloodless operative field.

Journal: :anesthesiology and pain medicine 0
joo hyeon oh department of anesthesiology and pain medicine, college of medicine, hallym university, seoul, korea sung jun hong department of anesthesiology and pain medicine, college of medicine, hallym university, seoul, korea sang soo kang department of anesthesiology and pain medicine, college of medicine, hallym university, seoul, korea sung mi hwang department of anesthesiology and pain medicine, college of medicine, hallym university, chuncheon, korea; department of anesthesiology and pain medicine, college of medicine, hallym university, chuncheon, korea. tel: +82-332405155, fax: +82-332510941

a-56-year-old woman underwent carpal tunnel release surgery under general anesthesia. thirty minutes after extubation, the patient complained of chest discomfort with dyspnea. swelling of the neck and upper anterior chest was observed. computed tomography of the chest showed tracheal rupture at the brachiocephalic trunk level, and bronchoscopy demonstrated a 5 cm linear tracheal defect in the p...

2016
Jack C. Buckley Adam P. Brown John S. Shin Kirsten M. Rogers Nir N. Hoftman

BACKGROUND Endotracheal tube security is a critical safety issue. We compared the mobility of an in situ endotracheal tube secured with adhesive tape to the one secured with a new commercially available purpose-designed endotracheal tube-holder device (Haider Tube-Guard). We also observed for the incidence of oropharyngeal or facial trauma associated with the 2 tube fixation methods. METHODS ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید