نتایج جستجو برای: electronic portal imaging device radiation therapy

تعداد نتایج: 2055089  

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak

abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was als...

2001
Martin Lachaine Biagio Gino Fallone

During a radiation therapy treatment, many factors may influence the proper delivery of a calculated dose distribution. Some of these factors include misalignment of the treatment beam with respect to the patient, external or internal patient motion, or inaccurate positioning of beam-modifying devices.1 In order to quantify these geometric inaccuracies during treatment, a portal image is typica...

2000
Michael G. Herman Jon J. Kruse Christopher R. Hagness

The Electronic Portal Imaging Device (EPID) provides localization quality images and computer-aided analysis, which should in principal, replace portal film imaging. Modern EPIDs deliver superior image quality and an array of analysis tools that improve clinical decision making. It has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the qual...

2015

Successful delivery of conformal fields requires stringent immobilization and treatment verification, as well as knowledge of the setup reproducibility. [1] Before coming OBI, electronic portal imaging detector was used to detect the setup errors. EPID images are not clear vision to identify correctly and immediately because they were produced by megavoltage X-ray during treatment setup. In OBI...

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

Journal: :iranian journal of radiation research 0
s. r. mahdavi medical physics department of iran university of medical sciences, tehran, iran e. jazayeri gharehbagh department of radiology and radiotherapy technology, school of allied health sciences, tehran university of medical sciences, tehran, iran b. mofid 3radiotherapy department of shahid beheshti university of medical sciences, tehran, iran a. h. jafari research center of biomedical technology and robotics, tehran university of medial sciences, tehran, iran a. r. nikoofar radiotherapy department of iran university of medical sciences, tehran, iran

background: to correct patient positioning errors (setup errors) during prostate cancer treatment using epid and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. materials and methods: fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field imrt planning technique. the p...

2018
Jie Li Angelo Piermattei Pei Wang Shengwei Kang Mingyong Xiao Bin Tang Xiongfei Liao Xin Xin Mattia Grusio Lucia Clara Orlandini

High conformal techniques such as intensity-modulated radiation therapy and volumetric-modulated arc therapy are widely used in overloaded radiotherapy departments. In vivo dosimetric screening is essential in this environment to avoid important dosimetric errors. This work examines the feasibility of introducing in vivo dosimetry (IVD) checks in a radiotherapy routine. The causes of dosimetric...

Fateme Shahedi, Hossein Akbari Mahdi Jamali Mahdi Mommen nezhad shahrokh Nasseri,

Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...