نتایج جستجو برای: echo planar imaging

تعداد نتایج: 526840  

Journal: :Magnetic resonance in medicine 2010
Robin M Heidemann David A Porter Alfred Anwander Thorsten Feiweier Keith Heberlein Thomas R Knösche Robert Turner

Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...

Journal: :NeuroImage 2007
Stefan J Kiebel Stefan Klöppel Nikolaus Weiskopf Karl J Friston

Dynamic causal modeling (DCM) of functional magnetic resonance imaging (fMRI) data allows one to make inferences about the architecture of distributed networks in the brain, in terms of effective connectivity. fMRI data are usually acquired using echo planar imaging (EPI). EPI sequences typically acquire slices at different times over a few seconds. DCM, in its original inception, was not infor...

Journal: :Magnetic resonance in medicine 2005
David W Carmichael Andrew N Priest Enrico De Vita Roger J Ordidge

A new method is presented that enables image acquisition to be segmented into two readouts. This is achieved using a new pulse sequence that creates two components of magnetization with different spatial profiles. Each component of the magnetization is measured in one of the readouts. This produces two images with complimentary "sensitivity profiles" and near identical contrast. The images can ...

Journal: :Magnetic resonance in medicine 2011
Stefan Hetzer Toralf Mildner Harald E Möller

A robust modification of echo-planar imaging dubbed double-shot echo-planar imaging with center-out trajectories and intrinsic navigation (DEPICTING) is proposed, which permits imaging at ultra-short echo time. The k-space data is sampled by two center-out trajectories with a minimal delay achieving a temporal efficiency similar to conventional single-shot echo-planar imaging. Intersegment phas...

Journal: :Magnetic Resonance in Medicine 2019

Journal: :Japanese Journal of Radiological Technology 1996

Journal: :Magnetic resonance in medicine 2002
Susanne Rieseberg Jens Frahm Jürgen Finsterbusch

Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced suscept...

Journal: :AJNR. American journal of neuroradiology 1998
K O Lövblad P M Jakob Q Chen A E Baird G Schlaug S Warach R R Edelman

PURPOSE Our objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base. METHODS Forty subjects who were refe...

Journal: :Magnetic resonance in medicine 2002
Hangyi Jiang Xavier Golay Peter C M van Zijl Susumu Mori

Motion sensitivity in diffusion-weighted imaging (DWI) can be effectively suppressed using single-shot echo-planar imaging (EPI). However, segmented (multishot) EPI is often used to increase resolution and reduce spatial distortions, which in turn increases susceptibility to brain motion. The sources of these residual motion artifacts in navigator-echo-corrected segmented EPI images of the brai...

Journal: :Magnetic resonance in medicine 2015
Avigdor Leftin Jens T Rosenberg Eddy Solomon Fabian Calixto Bejarano Samuel C Grant Lucio Frydman

PURPOSE This study quantifies in vivo ischemic stroke brain injuries in rats using ultrahigh-field single-scan MRI methods to assess variations in apparent diffusion coefficients (ADCs). METHODS Magnitude and diffusion-weighted spatiotemporally encoded imaging sequences were implemented on a 21.1 T imaging system, and compared with spin-echo and echo-planar imaging diffusion-weighted imaging ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید