Jason E. Matney Brent C. Parker Daniel W. Neck Greg Henkelmann Isaac I. Rosen

The purpose of this study was to quantify the performance and assess the utility of two different types of scanners for radiochromic EBT film dosimetry: a commercial flatbed document scanner and a widely used radiographic film scanner. We evaluated the Epson Perfection V700 Photo flatbed scanner and the Vidar VXR Dosimetry Pro Advantage scanner as measurement devices for radiochromic EBT film. ...

Journal: :Medical physics 2007
Alexandra Rink I Alex Vitkin David A Jaffray

The response of radiochromic film, GafChromic EBT, was investigated for dependence on x-ray beam energy using a previously reported real-time optical readout approach. X-ray beams of energy from 75 kVp to 18 MV were employed. The dose-induced change in optical density for the EBT film was compared to values obtained for GafChromic HS and MD-55 films, exposed under the same conditions. All respo...

Journal: :Physics in medicine and biology 2010
Ethan T Butson Tsang Cheung Peter K N Yu Martin J Butson

Ultraviolet radiation dosimetry has been performed with the use of a radiochromic film dosimeter called Gafchromic EBT for solar radiation exposure. The film changes from a clear colour to blue colour when exposed to ultraviolet radiation and results have shown that the colour change is reproducible within ±10% at 5 kJ m(-2) UV exposure under various conditions of solar radiation. Parameters te...

Journal: :Journal of radiation research 2012
Katsumi Shima Kunihiko Tateoka Yuichi Saitoh Junji Suzuki Yuji Yaegashi Kazunori Fujimoto Takuya Nakazawa Akihiro Nakata Tadanori Abe Sho Imai Kouichi Sakata Masato Hareyama

The post-exposure density growth (PEDG) is one of the characteristics of radiochromic film (RCF). In film dosimetry using RCF and a flatbed scanner, pixel values read out from the RCF are converted to dose (hereafter, film dose) by using a calibration curve. The aim of this study is to analyze the relationship between the pixel value read out from the RCF and the PEDG, and that between the film...

Hasan Nedaie Majid Shariari Zahra Anjomani,

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

Journal: :iranian journal of medical physics 0
zahra anjomani m.sc. in medical physics, nuclear engineering dept., shahid beheshti university, tehran, iran hasan nedaie assistant professor, radiotherapy physics dept., tehran university of medical science, tehran, iran majid shariari associate professor, nuclear engineering dept, shahid beheshti university, tehran, iran

introduction: nowadays new radiochromic films have an essential role in radiotherapy dosimetry. properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. material and methods: in this study, electron-beam dose distributions in homogenous and heterogeneous pha...

2007
Martina Fuss Eva Sturtewagen Carlos De Wagter Dietmar Georg

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

Journal: :Medical physics 2012
Slobodan Devic Nada Tomic Saad Aldelaijan Francois Deblois Jan Seuntjens Maria F Chan Dave Lewis

PURPOSE Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present resu...

2014
Mishra Subhalaxmi T. Palani Selvam

Relative absorbed dose energy response correction, R, for various radiochromic films in water phantom is calculated by the use of the Monte Carlo-based EGSnrc code system for high energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb. The corrections are calculated along the transverse axis of the sources (1-15 cm). The radiochromic films investigated are EBT, EBT2 (lot 020609 and lot 03110...