نتایج جستجو برای: drug eluting stent

تعداد نتایج: 620413  

Journal: :Arteriosclerosis, thrombosis, and vascular biology 2005
Rainer Wessely Jörg Hausleiter Cornelia Michaelis Birgit Jaschke Michael Vogeser Stefan Milz Boris Behnisch Thomas Schratzenstaller Magdalena Renke-Gluszko Michael Stöver Erich Wintermantel Adnan Kastrati Albert Schömig

OBJECTIVE The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. METHODS AND RESULTS The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating ...

2013
Sripal Bangalore Bora Toklu Nicholas Amoroso Mario Fusaro Sunil Kumar Edward L Hannan David P Faxon Frederick Feit

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

2011
Mahesh Bikkina Jayanth Koneru

The root cause of coronary artery disease is atherosclerosis, ie, intraluminal narrowing (stenosis) of the arteries that supply blood to tissues of the heart. The introduction of the drug-eluting stent over the past decade has revolutionized the field of interventional cardiology. It is used extensively in clinical practice for the treatment of coronary artery disease. The first drug-eluting st...

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

Journal: :The American journal of cardiology 2009
Christoph A Nienaber Ibrahim Akin Steffen Schneider Jochen Senges Thomas Fetsch Ulrich Tebbe Stefan N Willich Jürgen Stumpf Georg V Sabin Sigmund Silber Gert Richardt Karl-Heinz Kuck

The prospective multicenter German Drug-Eluting Stent (DES.DE) registry is an observational study to analyze and evaluate the therapeutic principle of the differential drug-eluting stents (sirolimus- and paclitaxel-eluting stents) and bare metal stents under real world conditions in the context of the German healthcare system. The baseline clinical and angiographic characteristics and follow-up...

Journal: :the journal of tehran university heart center 0
mohammad alidoosti tehran heart center, tehran university of medical sciences, tehran, iran. vahideh sharifnia tehran heart center, tehran university of medical sciences, tehran, iran. seyed ebrahim kassaian tehran heart center, tehran university of medical sciences, tehran, iran. alimohammad hajizeinali tehran heart center, tehran university of medical sciences, tehran, iran. hamidreza poorhosseini tehran heart center, tehran university of medical sciences, tehran, iran. mojtaba salarifar tehran heart center, tehran university of medical sciences, tehran, iran.

background: the biolimus-eluting stent (bes), with a biodegradable polymer, has not been previously compared with the everolimus-eluting stent (ees), as a second-generation drug-eluting stent (des).we sought to compare the 1-year outcome between the promus ™ stent (ees type) and the biomatrix ™ stent (bes type). methods: from march 2008 to september 2011, all patients treated with the promus™ s...

2014
Hiroshi Fujita Kenya Nasu Mitsuyasu Terashima Tsuyoshi Ito Tomomitsu Tani Takahiko Suzuki Nobuyuki Ohte

BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...

Journal: :iranian red crescent medical journal 0
j zamany cardiovascular research center, faghihi hospital, shiraz university of medical sciences, iran y mahmoody cardiovascular research center, faghihi hospital, shiraz university of medical sciences, iran +98-917-7203241, [email protected]; cardiovascular research center, faghihi hospital, shiraz university of medical sciences, iran +98-917-7203241, [email protected] ma ostavan cardiovascular research center, faghihi hospital, shiraz university of medical sciences, iran j n mahlangu haemophiliac comprehensive care centre, national health laboratory services, university of the witwatersrand, south africa ; haemophiliac comprehensive care centre, national health laboratory services, university of the witwatersrand, south africa

2009
Dirk Sibbing Karl-Ludwig Laugwitz Lorenz Bott-Flügel Jürgen Pache

Although safety profiles of sirolimus-eluting stents do not seem to differ in short-to-medium term from those of bare-metal stents, late stent thrombosis after deployment of drug-eluting stents has emerged as a potential safety concern in the era of high-pressure stent implantation. Here, we describe the case of a patient with acute myocardial infarction due to stent thrombosis of a sirolimus-e...

Journal: :Arquivos brasileiros de cardiologia 2009
Pedro A Lemos Bruno Moulin Marco A Perin Ludmilla A R R Oliveira J Airton Arruda Valter C Lima Antonio A G Lima Paulo R A Caramori Cesar R Medeiros Mauricio R Barbosa Fabio S Brito Expedito E Ribeiro Eulógio E Martinez

BACKGROUND We describe the rationale and design for the 'PercutAneous INTervention with biodegradable-polymer based paclitaxel-eluting or sirolimus-eluting versus bare stents for de novo coronary lesions - PAINT trial'. OBJECTIVES To evaluate two novel formulations of paclitaxel-eluting stent and the sirolimus-eluting stent against a stent with the same metallic structure but without polymer ...

نمودار تعداد نتایج جستجو در هر سال