نتایج جستجو برای: dpoae

تعداد نتایج: 421  

Journal: :Audiology & neuro-otology 2014
Nikolaus E Wolter Robert V Harrison Adrian L James

OBJECTIVES Mediated by the medial olivocochlear system (MOCS), distortion product otoacoustic emission (DPOAE) levels are reduced by presentation of contralateral acoustic stimuli. Such acoustic signals can also evoke a middle ear muscle reflex (MEMR) that also attenuates recorded DPOAE levels. Our aim is to clearly differentiate these two inhibitory mechanisms and to analyze each separately, p...

Journal: :Ear and hearing 2004
Sumitrajit Dhar Lauren A Shaffer

OBJECTIVES The use of a suppressor tone has been proposed as the method of choice in obtaining single-generator distortion product (DP) grams, the speculation being that such DP grams will be more predictive of hearing thresholds. Current distortion product otoacoustic emissions (DPOAE) theory points to the ear canal DPOAE signal being a complex interaction between multiple components. The effe...

2014
Ying Xiao Jian Wen Yanxia Bai Na Duan G X Jing

OBJECTIVES To investigate the effects of isoflurane and propofol on mean arterial pressure (MAP), cochlear blood flow (CoBF), distortion-product otoacoustic emission (DPOAE), and the ultrastructure of outer hair cells (OHCs) in guinea pig cochleae. METHODS Forty-eight male guinea pigs were randomly assigned to one of six treatment groups. Groups 1 to 3 were infused (i.v.) with a loading dose ...

Journal: :The Journal of the Acoustical Society of America 2011
Carolina Abdala Sumitrajit Dhar Radha Kalluri

Distortion product otoacoustic emissions (DPOAEs) measured in the ear canal represent the vector sum of components produced at two regions of the basilar membrane by distinct cochlear mechanisms. In this study, the effect of stimulus level on the 2f(1) - f(2) DPOAE phase was evaluated in 22 adult subjects across a three-octave range. Level effects were examined for the mixed DPOAE signal measur...

2004
David A. Zapala

A number of commercial distortion product otoacoustic emission (DPOAE) systems are available. Each system uses a slightly different signal processing approach . As a result, calculations commonly used to quantify the quality of collected DPOAE data (such as noise level and signal to noise ratio) differ across systems. In this report, the theory underlying DPOAE noise estimation is reviewed and ...

Journal: :Hearing research 1996
C Abdala Y S Sininger M Ekelid F G Zeng

Distortion product otoacoustic emission (DPOAE) iso-suppression tuning curves (STC) were generated in 15 normal-hearing adults and 16 healthy term-born neonates for three f2 frequencies. The 2f1-f2 DPOAE was elicited using f2/f1 = 1.2, LI = 1.2, LI = 65 and L2 = 50 dB SPL. A suppressor tone was presented at frequencies ranging from 1 octave below to 1/4 octave above f2 and varied in level until...

Journal: :Ear and hearing 2008
Kelly M Reavis David S Phillips Stephen A Fausti Jane S Gordon Wendy J Helt Debra Wilmington Gene W Bratt Dawn Konrad-Martin

OBJECTIVES (1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxicity depends on the type of drug administered (platinum or antibiotic), magni...

2014
Ujimoto Konomi Sohit Kanotra Adrian L James Robert V Harrison

BACKGROUND The two ears are linked with a neural pathway such that stimulation of one ear has a modulating effect on the contralateral cochlea. This is mediated by cochlear afferent neurons connecting with olivo-cochlear efferents. The monitoring of this pathway is easily achieved by measuring contralateral suppression of otoacoustic emissions, and there is some clinical value in the ability to...

Journal: :The Journal of experimental biology 2013
Emanuel C Mora Ariadna Cobo-Cuan Frank Macías-Escrivá Martha Pérez Manuela Nowotny Manfred Kössl

The mechanical tuning of the ear in the moth Empyreuma pugione was investigated by distortion-product otoacoustic emissions (DPOAE) and laser Doppler vibrometry (LDV). DPOAE audiograms were assessed using a novel protocol that may be advantageous for non-invasive auditory studies in insects. To evoke DPOAE, two-tone stimuli within frequency and level ranges that generated a large matrix of valu...

2003
Andrei N. Lukashkin Victoria A. Lukashkina P. Kevin Legan Guy P. Richardson Ian J. Russell

Role of the tectorial membrane revealed by otoacoustic emissions recorded from wild-type and transgenic Tecta ENT/ENT mice ABSTRACT Distortion product otoacoustic emissions (DPOAE) were recorded from wild-type mice and mutant Tecta ENT/ENT mice with detached tectorial membranes (TM), under combined ketamine/xylaxine anaesthesia. In Tecta ENT/ENT mice DPOAEs could be detected above the noise flo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید