نتایج جستجو برای: dosimetry calculation

تعداد نتایج: 109521  

Journal: :journal of biomedical physics and engineering 0
m sadeghi radiation research center, shiraz university, shiraz, iran s sina nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran r faghihi nuclear engineering department, school of mechanical engineering, shiraz university, shiraz, iran

lif, mg and ti cubical tld chips (known as tld-100) are widely used for dosimetry purposes. the repeatability of tl dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mgy) with 662kev photons of cs-137. a group of 40 cubical tld chips was randomly selected from a batch and the values of element correction coefficient (ecc) were obtained 4 times by irradiating them to doses...

2014
Parvin Mohammadyari Mehdi Zehtabian Sedigheh Sina Ali Reza Tavasoli Reza Faghihi

Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...

Journal: :Journal of Applied Clinical Medical Physics 2011

2010
Tzung-Chi Huang Ji-An Liang Thomas Dilling Tung-Hsin Wu Geoffrey Zhang

Thoracic cancer treatment presents dosimetric difficulties due to respiratory motion and lung inhomogeneity. Monte Carlo and deformable image registration techniques have been proposed to be used in four-dimensional (4D) dose calculations to overcome the difficulties. This study validates the 4D Monte Carlo dosimetry with measurement, compares 4D dosimetry of different tumor sizes and tumor mot...

2016
Ryan G Lafratta

Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE® dosimeter and the film and TLD system agreed with the plan to within 5%...

Journal: :iranian journal of radiation research 0
m. yazdani department of physics, tarbiat moallem university of sabzevar, sabzevar, iran a.a. mowlavi department of physics, tarbiat moallem university of sabzevar, sabzevar, iran

background: monte carlo determination of tg-43 brachytherapy dosimetry parameters and dose distribution calculation for 131cs source model cs-1 are presented in this study. materials and methods: the dose distribution was calculated around the 131cs model cs-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using mcnp code by monte carlo method. the percentage ...

2007
G. A. Wright C. J. Dean

The IRDF2002 dosimetry cross-section data are processed into very fine energy groups and added to the detector response library for the Monte Carlo code MCBEND. The IRDF2002 covariances are processed into broad groups to form a MCBEND detector covariance library. A number of benchmark experiments are analysed using MCBEND with both IRDF2002 and IRDF90 data and the results compared. Uncertaintie...

2012
Mahdi Sadeghi Pooneh Saidi Claudio Tenreiro

The term of brachytherapy, also known as “internal radiotherapy, sealed source radiotherapy, curietherapy or endocurietherapy” is from Greek work brachy means short distance and therapy (treatment) and also known as internal radiotherapy or sealed source radiotherapy. Brachytherapy is a special form of radiotherapy where a radioactive source is carefully placed on or inside the area to be treat...

Journal: :International journal of occupational safety and ergonomics : JOSE 2006
Daniele Andreuccetti Nicola Zoppetti

An overview of quasi-static electromagnetic dosimetry is presented. After an introductive description of quantities and standards and a quick look at experimental and analytical approaches, attention is focused on numerical dosimetry. The process that leads to the calculation of results is analyzed in its basic steps, including the representation of the human body by means of a realistic voxel ...

Journal: :Medical physics 2010
H Schiefer A Fogliata G Nicolini L Cozzi W W Seelentag E Born F Hasenbalg J Roth B Schnekenburger K Münch-Berndl V Vallet M Pachoud B Reiner G Dipasquale B Krusche M K Fix

PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ioniz...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید