نتایج جستجو برای: dose area product

تعداد نتایج: 1137676  

Journal: :Journal of the Korean Society of Radiology 2017

Journal: :iranian journal of radiation research 0
m.b. tavakoli department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran g.h fallah mohammadi department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran z. fallah mohammadi department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran z. shaneh department of medical physics and medical engineering, school of medicine, isfahan university of medical sciences, isfahan, iran

background: high level radiation areas have been recognized on various parts of the earth. mahallat hot spring region is one of these areas. study of exposure in these areas can be helpful in investigating the effects of ionizing radiation. internal and external exposure to the staff was studied. materials and methods: used materials and instruments include: rss-112 ionizing chamber for environ...

H. Zare, M. Nazery, M.T. Bahreyni Toosi,

Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...

Background: During interventional cardiology processes, patients especially women and children receive high radiation doses due to their sensitivity.Objective: In this study, we evaluated a pediatric patient dose separately in those undergone intervention cardiac procedure. Material and Methods: In this cross sectional study, a public hospital with 252 patients, Entrance Skin Dose (...

2014
M. H. Nassef

The objective of this study was to determine the Dose Area Product (DAP) for sample of 70 patients (40 Females and 30 Males) undergoing different types of digital radiography (DR) examinations at King Abdul-Aziz University Hospital (KAUH), Saudi Arabia. This study was done through implementing a quality control (QC) program initiated by The Center for Training and radiation protection, KAU. It ...

Journal: :Radiation protection dosimetry 2007
B Poppe H K Looe A Pfaffenberger N Chofor F Eenboom M Sering A Rühmann A Poplawski K Willborn

In this study, dose-area product (DAP) measurements in panoramic dental radiology have been performed in Germany. The results obtained in this study were proposed as diagnostic reference levels (DRLs). A representative number of dental panoramic units, both with digital and conventional image receptors, have been chosen. Common statistical parameters such as mean, standard deviation and 3rd qua...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2011
Mitsuhiro Nakamae Yoshiyuki Tatsumi Shigeaki Morioka Seiichi Masuda Yasutomo Kitanaka

Philips DigitalDiagnost, a digital radiographic system mounting flat panel detector (FPD), can display dose area data (DiDi dose) calculated by examination parameters. We evaluated its fundamental characteristics and compared the values of DiDi dose andactual measured data obtained by the area dose product meter (PD-4100L). Tendency of varied values of mAs, X-ray tube values and exposure area f...

Journal: :iranian journal of radiation research 0
m.t. bahreyni toosi medical physics research center, bu-ali research institute, mashhad university of medical sciences. mashhad, iran m. nazery medical physics, mashhad university of medical sciences. mashhad, iran h. zare medical physics research center, bu-ali research institute, mashhad university of medical sciences. mashhad, iran

background: application of dose-area product (dap) quantity has been increased in the clinical practice. dap is relatively easy to measure. dap has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. material and methods: in this study, measurements of dap were carried out in a sample of 421 adult patients who underwent conventiona...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید